Delta Electronics VFD-XXXE quick start Description of the Digital Keypad KPE-LE02 Optional

Page 6

C. PNP mode without external power

D. PNP mode with external power

NPN

NPN

Sw1

Sw1

 

PNP

PNP

 

Factory

Factory

setting

setting

 

+

 

24

 

Vdc -

Figure 5 RJ-45 Pins Definition for VFD*E*C Models

 

PIN

Signal

Description

 

 

1

CAN_H

CAN_H bus line (dominant high)

 

 

2

CAN_L

CAN_L bus line (dominant low)

 

 

3

CAN_GND

Ground / 0V /V-

 

 

4

SG+

485 communication

 

 

5

SG-

485 communication

 

 

7

CAN_GND

Ground / 0V /V-

 

Description of the Digital Keypad KPE-LE02 (Optional)

1

3

 

2

4

6

 

5

7

8

1Status Display

Display the driver's current status.

2LED Display

Indicates frequency, voltage, current, user defined units and etc.

3Potentiometer

For master Frequency setting.

4RUN Key

Start AC drive operation.

5UP and DOWN Key

Set the parameter number and changes the numerical data, such as Master Frequency.

6MODE

Change between different display mode.

7STOP/RESET

Stops AC drive operation and reset the drive after fault occurred.

8ENTER

Used to enter/modify programming parameters

English- 6

Image 6
Contents Preface Specifications Voltage Class 115V ClassGeneral Specifications Basic Wiring Diagram SL2 VT2 TL3 WT3+/B1 PNP mode without external power Signal DescriptionDescription of the Digital Keypad KPE-LE02 Optional Operation Steps of the Digital Keypad To shift dataTerminal Symbol Power Terminals and Control TerminalsFrame Power Terminals Torque Wire Wire Type Terminal ExplanationsSpecification for the Control Terminals Control Terminals ExplanationsFrame Control Terminals Torque Summary of Parameter Settings Group 0 User ParametersNot for VFD*E*C models Explanation Settings FactoryModels VFD*E*C modelsFor VFD*E*C models, the factory setting is Group 1 Basic ParametersExplanation Settings Factory Group 2 Operation Method Parameters AVI2UP/DOWN Explanation Settings Factory Setting For VFD*E*C modelsGroup 3 Output Function Parameters Not for VFD*E*C Group 4 Input Function ParametersQuick Stop Only for VFD*E*C models Setting is 23. For VFD*E*C For VFD*E*C models Models, the factoryBit5=1MI6 used by PLC Group 5 Multi-Step Speeds Parameters Group 6 Protection ParametersExplanation Settings Factory Group 7 Motor Parameters FLASetting Group 8 Special Parameters Group 9 Communication Parameters Only for VFD*E*C Models Address only for VFD*E*C modelsOnly for VFD*E*C Group 10 PID Control ParametersParameters for Extension Card MO4/RA4 MO2/RA2MO3/RA3 MO5/RA5Explanation Settings Quick Stop Only for VFD*E*C models Fault Codes Group 13 PG function Parameters for Extension CardPLC not for VFD*E*C models Overheating Over currentOver voltage OverloadGFF hardware error Fault Fault Descriptions Corrective Actions Name OverloadCC current clamp OV hardware error OC hardware errorTemperature sensor error Fault Fault Descriptions Corrective Actions NamePhase error PID feedback signal errorDimensions are in mm inch FrameH1 H Frame C Unit mm inch