Location and Function of Controls
Control panel terminology
a. The Local Keypad (built in RCU)
Gaining Access
The local keypad is built in into the rear of the projector. Push once on the door cover and it will open. It is possible to turn it 90°. This local keyboard has the same functions as the Remote Control Unit (RCU)
b. RCU control panel terminology
This remote control includes a battery powered infrared (IR) trans- mitter that allows the user to control the projector remotely.
This remote control is used for source selection, control, adaptation and
- picture controls (Brightness, Sharpness,....)
- picture geometry adjustments - convergence adjustments
Other functions of the remote control are:
- switching between standby and operational modes
- switching to "pause" (blanked picture, full power for immediate restarting)
- direct access to all connected sources
- variable adjustment speed : when pushing continuously on the control stick or the picture keys, the adjustment will be executed in an accelerated fashion.
9 0
7 8
5 6
34
12
-
-
-
- +
- +
pause/park
sharpness
tint
color
brightness
contrast
1
2
3
4
5
6
7
8
Back light key : when activated, all keys will be lit up and visible in the dark.
ADJ. : adjust key, to enter or exit the adjustment mode.
Address key (recessed key), to enter the address of the projector (between 0 and 9). Press the address key, followed by pressing one digit button between 0 and 9.
STBY : stand by button :
-to initiate remote power up operation
-to stop projection without main power off.
Pause :to blank the image, press PAUSE. The image disappears but full power is retained for immediate restart- ing.
Digit buttons : direct input selection.
Picture controls : use these buttons to obtain the desired level (see also 'Controlling') for each picture function.
TEXT : when adjusting one of the image controls during a meeting, the displayed bar scale can be removed by pressing 'TEXT' key first. To
32a
9
10
ENTER : to start up the adjustment mode or to confirm an adjustment or selection in the adjustment mode.
EXIT : to leave the adjustment mode or to scroll upwards when in the adjustment mode.
11
12
Control disk : to make menu selections when in the adjustment mode. Also allows to increment or decrement an adjustment in the adjustment mode.
control disk up = up arrow in the menus control disk down = down arrow in the menus
control disk to the right = arrow to the right on the menus control disk to the left = arrow to the left on the menus
RC operating indication : lights up when a button on the remote control is pressed. (This is a visual indicator to check the operation of the remote control)
5975628 BARCOGRAPHICS 1209S 010797