Service Mode
Dynamic Astigmatism (spot shape adjustment)
The spot shape adjustments correct the spot shape in 8 different areas on the screen and that for the three colors separately.
The spot shape is adjusted according to the axial axises and the diagonal axises when using the arrow keys on the RCU.
These adjustments have to be done on a dot pattern (e.g. the internally generated pattern) with standard line frequency (15 kHz). The adjustment values are stored in the EEPROM and remain the same for all frequencies.
| ||
Follow the next procedure :
Highlight 'Dyn. Astigmatism' by pushing the joy disk up or down and press ENTER to select.
EXIT returns to the path selection main menu.
Select the source type, selected source or genlock pattern, by highlighting the color for which the spot shape has to be corrected and press ENTER.
e.g. when selecting RED under 'on genlocked pattern', the projector
switches to a genlocked pattern. Press ENTER to continue adjustment.
Increase the contrast level using the Contrast Control to near maximum. Using that "+" Sharpness Key, defocus the image until the dots are large and easily visible. Press ENTER to continue to SEL.
Spot shapes
before dynamic
astigmatism correction
Diagonal | Spot shapes | |
astigmatism correction | after dynamic | |
(use the | and | astigmatism correction |
arrow key)
Axial
astigmatism correction
(use the and arrow key)
SERVICE MODE
IDENTIFICATION
COPY A BLOCK
DELTE A BLOCK
DELETE ALL BLOCKS
CHANGE PASSWORD
CHANGE LANGUAGE
RUN TIME
SET TO MIDPOSITION
CONVERGENCE MID
DYNAMIC ASTIGMATISM
MORE...
DYNAMIC ASTIGMATISM | |
ON SELECTED SOURCE | |
RED |
|
GREEN | |
BLUE | |
ON GENLOCKED PATTERN | |
RED |
|
GREEN | |
BLUE | |
Select pattern | or color |
with | or |
then <ENTER> | |
<EXIT> to | return. |
SEL : select the adjustment area on the screen where the spot shape has to be corrected.
Use the arrow keys to select one of the 8 areas. Press ENTER to continue to ADJ.
ADJ : adjust the spot shape in the axial or diagonal direction when using the arrow keys for the selected area. Adjust until the spot shape is circular.
Use the up and down arrow keys for the diagonal astigmatism adjustment and the left and right arrow keys for the axial astigmatism adjustment. Press ENTER to continue selecting a new area.
The adjustment direction (axial or diagonal) and adjustment value are
DYNAMIC ASTIGMATISM
First adjust the defocusing
of the image.
SEL : select area using arrow keys
ADJ : adjust axial astigmatism using
or astigmatism using
or
Toggle between SEL and ADJ
with <ENTER>
<ENTER> to continue
<EXIT> to return.