Barco R9002240, R9002249 Analog Picture Controls, Controlling chained projectors, Brightness

Page 20

Controlling

Analog Picture Controls

The analog picture controls can be adjusted with the RCU. The control keys are located on the lower right side of the key panel of the RCU and indicated with the name of the control and an icon.

When an analog picture control is pressed, a text box with bar scale and the function name of the control, e.g. 'brightness...' appears on the screen (only if 'TEXT' is ON). The length of the bar scale indicates the current memorized setting for this source. The bar scale changes as the + or - buttons of the control are pressed.

Brightness Control

A correct 'brightness' setting is important for good image reproduction. Adjust the brightness with the + button and - button (RCU) until the darkest parts of the picture appear black.

A bar scale gives a visual indication on the screen of the current brightness setting

BRIGHTNESS

36

while pressing on the above indicated keys. If the bar scale is not visible on the screen, press 'TEXT' key once and retry the above indicated keys.

The bar scale increases when pressing on the + button (higher brightness) and decreases when pressing on the - button (lower brightness).

Contrast Control

A correct 'contrast' setting is important for good image reproduction.

Adjust the contrast to the level you prefer, according to room lighting conditions. If the Contrast Control is too low, the picture will be too dim. If it is set too high, the picture may be too bright and not sharp.

A bar scale gives a visual indication on the screen of the current contrast setting while pressing the + or - buttons (RCU). If the bar scale is not visible on the screen, press 'TEXT' key once and retry the above indicated keys.

The bar scale increases when pressing on the + button (higher contrast) and decreases when pressing on the - button (lower contrast).

Color Saturation Control

Color saturation is only active for Video and S-Video Inputs. This control adjusts the color intensity of the picture. Adjust the color saturation using the + and - buttons (RCU). A bar scale gives a visual indication on the screen of the current color setting while pressing on the above indicated keys. If the bar scale is not visible on the screen, press 'TEXT' key once and retry the above indicated keys. The bar scale increases when pressing on the + button (richer colors) and decreases when pressing the - button (lighter colors).

Tint Control

Tint is only active for Video and S-Video Inputs. The Tint Control is effective only when using the NTSC 4.43 or NTSC 3.58 system. A bar scale gives a visual indication on the screen of the current tint setting while pressing the + or - buttons (RCU). If the bar scale is not visible on the screen, press the 'TEXT' key once and retry the above indicated keys buttons.

The bar scale increases when pressing on the + button (greener flesh tones) and decreases when pressing the - button (redder flesh tones).

Sharpness Control.

Sharpness control only active for Video and S-Video Inputs. A bar scale gives a visual indication on the screen of the current sharpness setting while pressing the + or - buttons (RCU). If the bar scale is not visible on the screen, press 'TEXT' key once and retry the above indicated keys. The bar scale increases when pressing on the + button (sharper picture) and decreases when pressing on the - button (softer picture).

Controlling chained projectors.

Projectors can be controlled individually as well as in a group.

For individual control see previous pages.

For group control of the projectors.

(input selection and analog picture control)

Program the 'zero address' into any RCU. Therefore, press on the address key and key in the address ("0") with the numeric keys on the RCU itself.

Once address '0' is pressed, all projectors will be controlled together until a new address is entered on the RCU. It is possible to have a common input selection and a common analog picture control.

Once a new address is entered, only the projector with that specific address will follow the new instructions.

Note : For group control, all projectors in a control group must be capable of receiving the IR signal from the controlling RCU at the same time.

4-4

 

5975688 BARCOVISION 1609S 131097

 

Image 20
Contents Vision 1609s R9002240 R9002249 Page Barco Projection Systems Date Art. No 131097 R5975688Page Table of Contents Appendix B Adjsutment Blocks and Source Numbers Safety Instructions On cleaning Location and Function of Controls Rear Panel TerminologyControl panel terminology Local Keypad built in RCU RCU control panel terminologyAC Power mains Cord Connection Power CheckSwitching On/Off ConnectionsRemaining Projector Warm UP Time Signal Input Connection to the ProjectorPleaseuse Exitto Leave this Procedure Connecting a Composite Video source to port Connecting a S-Video or Video source to portRED Green Blue Connecting a RGB Analog source to portConnecting a RGB Analog source to port 4/5 Connecting a Component Video source to port 4/5 Connecting an IR Remote Receiver to the projector Connecting a Rcvds 05 switcher to the projectorConnecting a VS05 switcher to the projector Battery installation in the RCU ControllingHow to use your RCU Projector AddressHow to display a projector address? How to program an address into the RCU?Projector AddressBrightness Analog Picture ControlsControlling chained projectors Start UP of the Adjustment Mode Adjustment ModeStart Up of the Adjustment Mode Random Access Adjustment Mode Starting-Up the Random Access Adjustment modeOverview Random Access Adjustment mode EnterFrom next Selecting Setup Pattern Internal Cross Hatch PatternRandom access adjustment mode selection menu Picture TuningColor Balance Color BalanceSync Fast/Slow Adjustment Clamp TuningPeaking PeakingPort 2 Video or S-Video Line Doubler optionColor Select Line Doubler onFocusing Focusing color selectMidpoint focusing Top image focusingPhase Geometry AdjustmentsHorizontal Phase Adjustment Raster Shift Adjustment Correct raster position Wrong raster positionLeft-Right east-west Adjustments LEFT-RIGHT E-WLeft Side Correction Seagull correctionLeft Side Correction Top-Bottom north-south Adjustments Horizontal Size Adjustment SizeVertical Linearity Adjustment Vertical Size AdjustmentBlanking Adjustments BlankingConvergence Adjustment Coarse Convergence AdjustmentConvergence RED on GreenFine Convergence Adjustment Vertical CornersRandom Access Adjustment Mode Service Mode Starting up the Service modeOverview flowchart Service mode ServiceCopy a Block IdentificationCopy a block Deletion of blocks Deleting block by blockDeletion of all blocks Delete a BlockChange password Change PasswordChange Language Run timeSet to midposition Undo MidpositionConvergence Mid Undo Convergence MidpositionDynamic Astigmatism spot shape adjustment Dynamic AstigmatismG2 Adjust Gamma correctionsCRT run in cycle CRT RUN in CycleProjector Warm Up CRT Drive ModeCRT Drive Mode MESSAGES, Warnings and Failures InputSource Projector AddressWait Iris FAN FailedOptions Magik Interface Ceiling Mount kit CM100Orbiting Kit Line Doubler KitOrbiting Mode Toggle Switches OrbitingOrbiting option Master/Slave ToggleOrbiting Alignment Adjustment procedure Stand-Alone projectorOrbiting Speed Toggle only in Master Orbiting Adjustment procedure multiple projector installations Orbiting Source numbers 90 Adjustment Blocks and Source Numbers 90Adjustment Blocks memory blocks Adjustment Blocks and Source Numbers Insert Card