Single Desktop

On Windows systems, the single desktop supports the Dome E3, Dome E3c, and Dome E5 displays running the Dome DX2 controller. From one display controller, you can run a single desktop across two Dome EX displays.

The procedures in this section show you how to complete the initial installation of single desktop and how to change your system configuration to move from dual-headed display to single desktop.

On the display controller, switch 3 on the DIP switch must be in the ON position for each procedure.

To set the display resolution

After you install the display controller and driver, use the Dome tab to set the display resolution for single desktop.

1Right-click the desktop, and select Properties > Settings. The Settings tab appears.

2Select the Plug and Play Monitor on Dome DX2/PCI Properties from the Display list. Make sure the box for Extend my Windows desktop onto this monitor is checked. Click Apply.

3 Select Advanced > Dome.

4In the resolution field, choose the resolution for single desktop.

5 Click OK until you return to the desktop.

30 Dome EX Display

Image 40
Contents Dome EX Display User’s GuidePlanar Systems, Inc. All rights reserved Contents Product Information Symbol explanations Intended useSafety precautions Safety tipsUnpacking and handling tips Preventing fire and injuryCleaning the display Shipping/storing the display Disposal informationDVI cable About the Display System Requirements Display Components Orientation mode Display PositionsTilt range Height range Viewing angleDesk Stand Features Stand height lockStand cable cover USB hubInstalling the Display Set the DIP Switch on the Dome DX2 Board TipsInstall the Display Controller To install the display controllerConnect the Video and Power Cables To connect the cablesInstall the Dome DX Display Driver To install the driverTo enable the display To change the display propertiesTo set the resolution and palette Auto-orientationTo set brightness To set driver optionsInstall the AX3 Display Driver To configure the displayTo set the display mode manually To adjust the display propertiesTo use a dual-display configuration Appendix Troubleshooting Problem Possible Cause SolutionDome E2 Specification Category Characteristic Item SpecificationReliability Power SupplyEnvironment Dome E3 Specification ModelDome E3 Specification Dome E3 Specification EMI shielding No emission of low-level radiation Temperature Dome E3c Specification Display Mtbf 30,000 hours Backlight Dome E5 Specification Dome E5 Specification Video Modes Connector Ports Details of DIN connectorsLED Status Lights LED a status information after initial power-on Power-up sequence information from LEDLED B status information after initial power-on To set the display resolution Single DesktopTo change the configuration to single desktop Restoring dual headsAuto-Installation System configuration requirementInstallation options Prompting user response during Fastinst.bat To remove the Dome DX driver Display Driver RemovalTo remove the AX3 driver Power Management Grayscale Palette Options Palette options with multiple displays Desktop iconsDynamic gray palette Nonlinear static gray paletteStatic gray palette Index Using single desktop Regulatory Compliance Canada, European Union, United StatesPage Fax + 358 9 420 EU Declaration of Conformity for Medical Application FCC Compliance Statement Australian ChinaJapan KoreaStandard Warranty Return Procedure Standard WarrantySummary Summary Limitations and Exclusions of Dome Displays Limitation of Implied WarrantiesExclusion of Damages Effect of Local LawMedicalsales@planar.com Medicalsupport@planar.com