Canopy T1/E1 Multiplexer | September 2004 |
| T1/E1 Multiplexer FPGA Version 3.4 |
2.4.6Configure Timing
Before the timing may be configured, you need to determine the network timing scheme to be used. You also need to identify the master and slave devices for the
| Procedure 13: Configuring timing using the CLI |
|
|
Action | Steps |
|
|
Log in | Press Enter. |
| At the username prompt, enter admin. |
| At the password prompt, enter password. |
|
|
Set master clock | NOTE: This is the master clock reference for all four T1/E1 lines. |
reference line | The default setting is T1/E1 Port 1. |
| Enter set master clock reference line [1/2/3/4] |
| where |
| [1/2/3/4] represents T1/E1 ports 1 through 4. |
| RESULT: The system responds |
| Clk ref line; [1,2,3,4] |
|
|
Set backup clock | NOTE: This is the optional backup clock reference for all four T1/E1 lines. The |
reference line | backup clock reference becomes active only when the master clock reference |
| line is unavailable. The default setting is T1/E1 Port 2. |
| Enter set secondary clock reference line [1/2/3/4] |
| where |
| [1/2/3/4] represents T1/E1 ports 1 through 4. |
| RESULT: The system responds |
| Backup clk ref line; [1/2/3/4] |
|
|
Issue 3 | Page 44 of 73 |