Canopy T1/E1 Multiplexer | September 2004 |
| T1/E1 Multiplexer FPGA Version 3.4 |
3.2T1/E1 ALARMS
Each T1/E1 channel has alarms for line code violation (BPV), receive loss of signal (LOS), and alarm indication signal (AIS) detection.
Follow these steps to display the alarms using the CLI.
Procedure 23: Displaying the alarms using the CLI
Action
Log in
View T1/E1 Alarms
Log off
Steps
Press Enter.
At the username prompt, enter admin.
At the password prompt, enter password.
Enter get alarms.
The system responds displays alarms for all 4 T1/E1 ports, as in the following example:
Line1:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
Line2:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
Line3:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
Line4:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
FPGA: 00
Enter lo.
RESULT: The system responds goodbye.
end of procedure
Issue 3 | Page 54 of 73 |