VXI VM4016 user manual Outputpolarityexternalinterrupt

Page 32

VXI Technology, Inc.

OUTPUT:POLARITY:EXTERNAL:INTERRUPT

The output polarity external interrupt command sets the polarity of the front panel interrupt output. When the poarity is set to normal, the output will be low when there is an interrupt event. When the polarity is set to invert, the output will be high when there is an interrupt event.

OUTPut:POLarity:EXTernal:INTerrupt <polarity>

Where <polarity> is either

 

NORMal or INVert.

 

 

EXAMPLES

 

OUTPut:POLarity:EXTernal:INTerrupt NORM

Sets the external interrupt output

 

polarity to a low pulse (NORMal),

 

when an interrupt occurs.

OUTPut:POLarity:EXTernal:INTerrupt?

Returns the external interrupt

NORM

output polarity as NORMal.

OUTP:POL:EXT:INT INV

Sets the external interrupt output

 

polarity to INVert.

OUTP:POL:EXT:INT?

Returns the polarity of the external

INV

interrupt output as INVert.

32

VM4016 Programming

Image 32
Contents VM4016 Page Table of Contents VXI Technology, Inc Warranty Limitation of WarrantyCertification Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCGeneral Safety Instructions Terms and SymbolsThis product. Product should be inspected or serviced Support Resources VXI Technology, Inc VM4016 Preface Introduction IntroductionDescription Front Panel LayoutVM4016 Block Diagram VM4016 General Specifications IRQ OutputPreparation for USE InstallationCalculating System Power and Cooling Requirements Front Panel Interface Wiring Setting the Chassis Backplane JumpersSetting the Logical Address Signal PIN Number Analog Comparator PIN Outs1631 Examples of Scpi Commands FETCHCONDITIONED? ProgrammingFETCHLATCHED? FETCHRAW? Inhousepseudo Inhouseregint InhouseregintInhouseregenable Inhouseclearlatch Inputdebounce ExamplesInputmask INPMASK?INPutMASKINTerrupt boolean Where boolean is 0 OFF 1 on InputmaskinterruptInputoffset INPOFFS?Inputpolarity INPutPOLarity NORM,@35Inputrange Outputpolarityexternalinterrupt Outputpolarityexternallatched Application Examples ExampleCommands Description Single Channel OperationControl Page Bracketing a Voltage Sets the external interrupt output to be active highBracketing AN Input Voltage Page Register Access Examples Register MAPFor example Pseudo Register Access VXIPLUG&PLAY Driver Examples VM4016 Programming VXI Technology, Inc Command Dictionary Alphabetical Command ListingIeee 488.2 Common Commands Instrument Specific Scpi Commands NormalScpi Required Commands Command Dictionary Query ParametersCommon Scpi Commands CLSESE Response DescriptionESR? IDN? OPC Query Parameters Query Response DescriptionRST SRE STB? TRG TST? WAI OPCInstrument Specific Scpi Commands FETChCONDitioned?FETChLATChed? FETChRAW? Inhouseclearlatch Inhousepseudo Inhouseregint Inhouseregenable INPutDEBounce INPutMASK INPutMASKINTerrupt INPutOFFSet INPutPOLarity INPutRANGe OUTPutPOLarityEXTernalINTerrupt OUTPutPOLarityEXTernalLATChed Required Scpi Commands STATusOPERationCONDition?STATusOPERationENABle STATusOPERationEVENt? STATusPRESet STATusQUEStionableCONDition? STATusQUEStionableENABle STATusQUEStionableEVENt SYSTemERRor? SYSTemVERSion? Theory of Operation Input Range Control Relay Signal Comparison Interrupt Generation Interrupt Generation Index OUTPutPOLarityEXTernalLATChed