The INHOUSE:PSEUDO command controls the use of the register interface. Pseudo set true specifies that pseudo register interface should be used. Pseudo set false specifies that the hardware register interface should be used. The value set takes effect next time the unit powers up [does not take effect immediately]. The pseudo register interface allows the use of REG_ENABLE and CLEAR_LATCH capability from the registers. Although the hardware register interface is much faster than the pseudo register interface, it lacks the above two features. It is important to note that when the module is shipped from the factory, pseudo is set to 1. It is also important to note that all letters of the command must be provided as there is no short form for this command.

INHOUSE:PSEUDO <boolean>

Where <boolean> is 0 OFF 1 ON.

 

 

EXAMPLES

 

INHOUSE:PSEUDO 1

Sets the pseudo register interface ON. (The

 

unit must be powered for the change to take

 

effect.)

INHOUSE:PSEUDO?

Returns 1 which states that the register

1

interface is set to pseudo.

22

VM4016 Programming

Image 22
Contents VM4016 Page Table of Contents VXI Technology, Inc Certification WarrantyLimitation of Warranty Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCGeneral Safety Instructions Terms and SymbolsThis product. Product should be inspected or serviced Support Resources VXI Technology, Inc VM4016 Preface Introduction IntroductionDescription Front Panel LayoutVM4016 Block Diagram VM4016 General Specifications IRQ OutputCalculating System Power and Cooling Requirements InstallationPreparation for USE Setting the Logical Address Setting the Chassis Backplane JumpersFront Panel Interface Wiring Signal PIN Number Analog Comparator PIN Outs1631 Examples of Scpi Commands FETCHCONDITIONED? ProgrammingFETCHLATCHED? FETCHRAW? Inhousepseudo Inhouseregint InhouseregintInhouseregenable Inhouseclearlatch Inputdebounce ExamplesInputmask INPMASK?INPutMASKINTerrupt boolean Where boolean is 0 OFF 1 on InputmaskinterruptInputoffset INPOFFS?Inputpolarity INPutPOLarity NORM,@35Inputrange Outputpolarityexternalinterrupt Outputpolarityexternallatched Application Examples ExampleCommands Description Single Channel OperationControl Page Bracketing a Voltage Sets the external interrupt output to be active highBracketing AN Input Voltage Page Register Access Examples Register MAPFor example Pseudo Register Access VXIPLUG&PLAY Driver Examples VM4016 Programming VXI Technology, Inc Command Dictionary Alphabetical Command ListingIeee 488.2 Common Commands Instrument Specific Scpi Commands NormalScpi Required Commands Command Dictionary Query ParametersCommon Scpi Commands CLSESE Response DescriptionESR? IDN? OPC Query Parameters Query Response DescriptionRST SRE STB? TRG TST? WAI OPCInstrument Specific Scpi Commands FETChCONDitioned?FETChLATChed? FETChRAW? Inhouseclearlatch Inhousepseudo Inhouseregint Inhouseregenable INPutDEBounce INPutMASK INPutMASKINTerrupt INPutOFFSet INPutPOLarity INPutRANGe OUTPutPOLarityEXTernalINTerrupt OUTPutPOLarityEXTernalLATChed Required Scpi Commands STATusOPERationCONDition?STATusOPERationENABle STATusOPERationEVENt? STATusPRESet STATusQUEStionableCONDition? STATusQUEStionableENABle STATusQUEStionableEVENt SYSTemERRor? SYSTemVERSion? Theory of Operation Input Range Control Relay Signal Comparison Interrupt Generation Interrupt Generation Index OUTPutPOLarityEXTernalLATChed