VXI VM4016 user manual This product. Product should be inspected or serviced

Page 8

 

 

VXI Technology, Inc.

WARNINGS (CONT.)

 

 

Avoid Electric Shock

To avoid electric shock or fire hazard, do not operate this

 

product with the covers removed. Do not connect or

 

disconnect any cable, probes, test leads, etc. while they are

 

connected to a voltage source. Remove all power and

 

unplug unit before performing any service. Service should

 

only be performed by qualified personnel.

Ground the Product

This product is grounded through the grounding conductor

 

of the power cord. To avoid electric shock, the grounding

 

conductor must be connected to earth ground.

Operating Conditions

To avoid injury, electric shock or fire hazard:

 

-

Do not operate in wet or damp conditions.

 

-

Do not operate in an explosive atmosphere.

 

-

Operate or store only in specified temperature range.

 

-

Provide proper clearance for product ventilation to

 

 

prevent overheating.

 

-

DO NOT operate if you suspect there is any damage to

 

 

this product. Product should be inspected or serviced

Improper Use

 

only by qualified personnel.

 

The operator of this instrument is advised that if

 

 

equipment is used in a manner not specified in this

manual, the protection provided by this equipment be may be impaired.

8

VM4016 Preface

Image 8
Contents VM4016 Page Table of Contents VXI Technology, Inc Warranty Limitation of WarrantyCertification Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCGeneral Safety Instructions Terms and SymbolsThis product. Product should be inspected or serviced Support Resources VXI Technology, Inc VM4016 Preface Introduction IntroductionDescription Front Panel LayoutVM4016 Block Diagram VM4016 General Specifications IRQ OutputPreparation for USE InstallationCalculating System Power and Cooling Requirements Front Panel Interface Wiring Setting the Chassis Backplane JumpersSetting the Logical Address Signal PIN Number Analog Comparator PIN Outs1631 Examples of Scpi Commands FETCHCONDITIONED? ProgrammingFETCHLATCHED? FETCHRAW? Inhousepseudo Inhouseregint InhouseregintInhouseregenable Inhouseclearlatch Inputdebounce ExamplesInputmask INPMASK?INPutMASKINTerrupt boolean Where boolean is 0 OFF 1 on InputmaskinterruptInputoffset INPOFFS?Inputpolarity INPutPOLarity NORM,@35Inputrange Outputpolarityexternalinterrupt Outputpolarityexternallatched Application Examples ExampleCommands Description Single Channel OperationControl Page Bracketing a Voltage Sets the external interrupt output to be active highBracketing AN Input Voltage Page Register Access Examples Register MAPFor example Pseudo Register Access VXIPLUG&PLAY Driver Examples VM4016 Programming VXI Technology, Inc Command Dictionary Alphabetical Command ListingIeee 488.2 Common Commands Instrument Specific Scpi Commands NormalScpi Required Commands Command Dictionary Query ParametersCommon Scpi Commands CLSESE Response DescriptionESR? IDN? OPC Query Parameters Query Response DescriptionRST SRE STB? TRG TST? WAI OPCInstrument Specific Scpi Commands FETChCONDitioned?FETChLATChed? FETChRAW? Inhouseclearlatch Inhousepseudo Inhouseregint Inhouseregenable INPutDEBounce INPutMASK INPutMASKINTerrupt INPutOFFSet INPutPOLarity INPutRANGe OUTPutPOLarityEXTernalINTerrupt OUTPutPOLarityEXTernalLATChed Required Scpi Commands STATusOPERationCONDition?STATusOPERationENABle STATusOPERationEVENt? STATusPRESet STATusQUEStionableCONDition? STATusQUEStionableENABle STATusQUEStionableEVENt SYSTemERRor? SYSTemVERSion? Theory of Operation Input Range Control Relay Signal Comparison Interrupt Generation Interrupt Generation Index OUTPutPOLarityEXTernalLATChed