1.0 Warning and Limited Warranty

WARNING!

FW MURPHY has made efforts to ensure the reliability of the Centurion Controller and to recommend safe usage practices in system applications. Please note that in any application, operation and controller failures can occur. These failures may result in full control outputs or other outputs which may cause damage to or unsafe conditions in the equipment or process connected to the Centurion Controller. Good engineering practices, electrical codes, and insurance regulations require that you use independent external protective devices to prevent potentially dangerous or unsafe condi- tions. Assume that the Centurion Controller can fail with outputs full on, outputs full off, or that other unexpected conditions can occur.

Please read the following information before installing the Centurion Controller. This installation information is intended for Centurion Controller. A visual inspection of this product before installation for any damage during shipping is recommended.

Disconnect all power and be sure machine is inoperative before beginning installation.

Installation is to be done only by qualified technician.

Observe all Warnings and Cautions at each section in these instruc- tions.

Device shall be wired in accordance with Class I, Division 2 wiring methods.

This equipment is suitable for use in Class I, Division 2, Groups B, C, and D hazardous Areas.

WARNING–Explosion Hazard–Substitution of components may impair suitability for Class I, Division 2.

Please contact FW MURPHY immediately if you have any questions.

Warranty

A limited warranty on materials and workmanship

is given with this FW Murphy product.

A copy of the warranty may be viewed or printed by going to

www.fwmurphy.com/support/warranty.htm

MURPHY, the Murphy logo, Centurion and C3 are registered and/or common law trademarks of Murphy Industries, Inc.

This document, including textual matter and illustrations, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2004 Murphy Industries, Inc.

Windows®. Modbus® and other third party product or trade names referenced herein are the property of their respective owners and are used for identification purposes only.

CE-05171N page 2 of 44

Image 2
Contents Centuriontm Warranty Table of Contents Communications Optional Components Basic Components and Key Features of the C3TM SeriesOverview Input/Output Types Digital Inputs DIAnalog Inputs AI Thermocouple Inputs TCMagnetic Pickup MPU Digital Outputs doC3-1-A Hazardous Area Operation Analog Outputs AOMounting the Centurion Controller Hardware Installation and WiringPower Supply Wiring Power Centurion C3-1 I/O Module Mounting the Centurion C3-3 DisplayWiring the Centurion C3-3 Display Wiring the Centurion C3-1/C3-2 TTD-98055N page 14 Features Home ESC ACK Fn Function KeyRUN Stop RUN/STOP Test Operational/Process Information Area Status AreaDisplay VER Mconfig PRO VEROperational Screens Controller VersionCooler Temperature Event History Panel ESD Panel Reset LOW Suct PressDISC. Temperature Shutdown History Panel ESDOIL PRS WTR Temp PSI Battery ENG SpeedAmbient Temperature VDCENTER-ACCEPT ESC-CANCEL Setup Screens and MenusEnter Password Digital Inputs Digital Outputs SetupAnalog Inputs Setup Digital InputAnalog Output 1 Setup Screen Analog Input 1 Setup ScreenAnalog Outputs Setup ANOUT01 ENTER-SUBMENU More Menus ESC Exit this MenuThermocouple 1 Setup Thermocouple Offset Thermocouple SetupThermocouple 1 Setup Type Offset Thermocouple00060 General Timer SetupGeneral Timer Setup Screen More MenuMaintenance Timer Setup Time Remaining Change OIL Maintenance Timer SetupMaintenance Timer Setup Screen RESET-RESET Timer ESC-EXIT this MenuControl Output 1 Setup Setpoints Setup ENTER-SUBMENU More MenusSetpoints Setup LO Suct PRS Control Output Throttle ENTER-MENU More MenuPID 1 Setup Screen PID Setup ENTER-SUBMENU More MenusPID Setup Screen 00004Port Response Delay Port 1 Baud Rate Lube NO-FLOW Status Cycle TIME-INPUT # Prev NO-FLOW Input # 1 Setup Cycle Time SEC Total CyclesCycle Timer SEC More Menus Super User Menu Screen 28%YES Diagnostico-Digital Inputs Screen Digital Input Status =CLOSEDMust be in Test Mode ESC-CANCEL Analog Output Status AI 1 ENG SpeedENTER-EDIT More Menus PID Diagnostics ENTER-SUBMENU More MenusCommunication Status Modbus Register Suction PID ESC-EXITAdditional Navigational Aids Remote Mode Commands Reset and RUN/STOPCommunications Communication PortsPort 2 USB Firmware Update Mode Power and COM Link Must be Maintained Firmware Download ScreenComm Fail Screen Invalid Configuration Press Setup to Access Download MenuConfiguration Fault Screen Modbus Protocol Glossary Terminal EmulatorAppendices Back Panel LED DescriptionHow To Order