Murphy CE-05171N manual Appendices, Back Panel LED Description

Page 43

9.0Appendices

9.1Back Panel LED Description

There are a total of seven (7) LED indicators on the back panel, labeled as follows:

(Port 1)

TX – Turned on while Port 1 is transmitting data. RX – Turned on while Port 1 is receiving data.

(Port 2)

TX – Turned on while Port 2 is transmitting data. RX – Turned on while Port 2 is receiving data.

USB LINK – Turns on while there is a USB connection to a computer.

STAT 1 –Turns on for one half second and then turns off for one half second, repeating as long as there is a valid configuration running.

Note: This indicator is not active while the bootloader is running.

STAT 2 – This LED is only active while the bootloader is running. It flashes briefly three times when the bootloader starts up and then stays on until leaving the bootloader.

9.2 Controller Accuracies, and Tolerances

Refer to the Centurion Configurable Controller Specification Sheet for a detailed breakdown of specifications.

9.3 Restrictions on Numeric Values in Gage and PID Monitor Screens

Due to a combination of the limited space and the spirit of the design objectives, there are certain restrictions imposed upon the formatted size of numbers in C3-3 Display screens.

Positive numbers with no decimals can be displayed with up to four digits.

Negative numbers are limited to three digits.

Numbers of either sign with a decimal place are limited to three digits.

Numbers with more than two decimal places will not be displayed at all, but will be replaced with dashes.

If a number with decimals is larger than the imposed limits, the display algorithm will attempt to adjust the precision so as to display as many of the most significant digits as possible.

9.4 Set Up Sheet

Refer to The Centurion Configuration Worksheet for a detailed workbook to document field changes to configuration parameters.

CE-05171N page 43 of 44

Image 43
Contents Centuriontm Warranty Table of Contents Communications Overview Basic Components and Key Features of the C3TM SeriesOptional Components Digital Inputs DI Input/Output TypesThermocouple Inputs TC Analog Inputs AIDigital Outputs do Magnetic Pickup MPUC3-1-A Analog Outputs AO Hazardous Area OperationMounting the Centurion C3-3 Display Hardware Installation and WiringPower Supply Wiring Power Centurion C3-1 I/O Module Mounting the Centurion ControllerWiring the Centurion C3-3 Display Wiring the Centurion C3-1/C3-2 TTD-98055N page 14 Features Fn Function Key Home ESC ACKRUN Stop RUN/STOP Test Status Area Operational/Process Information AreaController Version Mconfig PRO VEROperational Screens Display VERShutdown History Panel ESD Event History Panel ESD Panel Reset LOW Suct PressDISC. Temperature Cooler TemperatureVDC Battery ENG SpeedAmbient Temperature OIL PRS WTR Temp PSIEnter Password Setup Screens and MenusENTER-ACCEPT ESC-CANCEL Digital Input Digital Outputs SetupAnalog Inputs Setup Digital InputsESC Exit this Menu Analog Input 1 Setup ScreenAnalog Outputs Setup ANOUT01 ENTER-SUBMENU More Menus Analog Output 1 Setup ScreenThermocouple Thermocouple SetupThermocouple 1 Setup Type Offset Thermocouple 1 Setup Thermocouple OffsetMore Menu General Timer SetupGeneral Timer Setup Screen 00060RESET-RESET Timer ESC-EXIT this Menu Maintenance Timer SetupMaintenance Timer Setup Screen Maintenance Timer Setup Time Remaining Change OILControl Output Throttle ENTER-MENU More Menu Setpoints Setup ENTER-SUBMENU More MenusSetpoints Setup LO Suct PRS Control Output 1 Setup00004 PID Setup ENTER-SUBMENU More MenusPID Setup Screen PID 1 Setup ScreenPort Response Delay Port 1 Baud Rate Cycle Timer SEC More Menus NO-FLOW Input # 1 Setup Cycle Time SEC Total CyclesLube NO-FLOW Status Cycle TIME-INPUT # Prev YES 28%Super User Menu Screen Digital Input Status =CLOSED Diagnostico-Digital Inputs ScreenAnalog Output Status AI 1 ENG Speed Must be in Test Mode ESC-CANCELSuction PID ESC-EXIT PID Diagnostics ENTER-SUBMENU More MenusCommunication Status Modbus Register ENTER-EDIT More MenusCommunication Ports Remote Mode Commands Reset and RUN/STOPCommunications Additional Navigational AidsPort 2 USB Firmware Download Screen Firmware Update Mode Power and COM Link Must be MaintainedConfiguration Fault Screen Invalid Configuration Press Setup to Access Download MenuComm Fail Screen Modbus Protocol Terminal Emulator GlossaryBack Panel LED Description AppendicesHow To Order