Murphy CE-05171N manual How To Order

Page 44

How To Order

Selecting a Centurion Configurable Controller C3 Series Model:

1.Specify one C3-1Main I/O Module from Table A

Main I/O Module

Model: C3-1

Table A: C3-1 Main module Options

Model

Specifications

 

 

C3-1

no analog outputs

 

 

C3-1-A

two analog outputs

 

 

2.Specify one (optional) C3-2Expansion I/O Module

Expansion I/O Module

Model: C3-2

(optional)

3.Specify one (optional) C3-3Display Module

Display Module

Model: C3-3

(optional)

The minimum system requirements:

C3-1Main I/O Module

Display capable of Modbus communications

The Murphy C3-3Display Module is a highly integrated HMI for use with the C3 Series system and is recommended for most customers.

Some systems may require additional I/O which is available on the C3-2Expansion I/O Module.*

* Only one C3-2 Expansion I/O Module can be used with each C3 System.

Accessories

Configuration Software

MConfig Pro - Configuration software for modifying sequence of operation, set points, timers, faults, and *displays for Centurion. Includes file transfer utilities for configuration

and firmware upgrades.

* Display configuration and other settings for display are only for use with the C3-3 Display Module

Replacement Parts and Assemblies

C3-1 Plug Kit

(00000504)

Printed Replacement Terminal Plugs for Centurion (C3-1)

Main I/O Module

C3-2 Plug Kit

(00000505)

Printed Replacement Terminal Plugs for Centurion (C3-2)

Expansion I/O Module

C3-3 Plug Kit

(00000543)

Printed Replacement Terminal Plugs for Centurion (C3-3)

Display Module

Choke

(50000774)

Ignition Noise (Choke) Filter

 

FW Murphy

P.O. Box 470248

Tulsa, Oklahoma 74147 USA

+1 918 317 4100 fax +1 918 317 4266 e-mailsales@fwmurphy.com

www.fwmurphy.com

CONTROL SYSTEMS & SERVICES DIVISION

P.O. Box 1819; Rosenberg, Texas 77471; USA +1 281 633 4500 fax +1 281 633 4588 e-mailsales@fwmurphy.com

MURPHY DE MEXICO, S.A. DE C.V.

Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384

+52 444 8206264 fax +52 444 8206336 Villahermosa Office +52 993 3162117 e-mailventas@murphymex.com.mx www.murphymex.com.mx

FRANK W. MURPHY, LTD.

Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. +44 1722 410055 fax +44 1722 410088 e-mailsales@fwmurphy.co.uk www.fwmurphy.co.uk

Printed in U.S.A.

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

CE-05171N page 44 of 44

Image 44
Contents Centuriontm Warranty Table of Contents Communications Optional Components Basic Components and Key Features of the C3TM SeriesOverview Input/Output Types Digital Inputs DIAnalog Inputs AI Thermocouple Inputs TCMagnetic Pickup MPU Digital Outputs doC3-1-A Hazardous Area Operation Analog Outputs AOHardware Installation and Wiring Power Supply Wiring Power Centurion C3-1 I/O ModuleMounting the Centurion Controller Mounting the Centurion C3-3 DisplayWiring the Centurion C3-3 Display Wiring the Centurion C3-1/C3-2 TTD-98055N page 14 Features Home ESC ACK Fn Function KeyRUN Stop RUN/STOP Test Operational/Process Information Area Status AreaMconfig PRO VER Operational ScreensDisplay VER Controller VersionEvent History Panel ESD Panel Reset LOW Suct Press DISC. TemperatureCooler Temperature Shutdown History Panel ESDBattery ENG Speed Ambient TemperatureOIL PRS WTR Temp PSI VDCENTER-ACCEPT ESC-CANCEL Setup Screens and MenusEnter Password Digital Outputs Setup Analog Inputs SetupDigital Inputs Digital InputAnalog Input 1 Setup Screen Analog Outputs Setup ANOUT01 ENTER-SUBMENU More MenusAnalog Output 1 Setup Screen ESC Exit this MenuThermocouple Setup Thermocouple 1 Setup Type OffsetThermocouple 1 Setup Thermocouple Offset ThermocoupleGeneral Timer Setup General Timer Setup Screen00060 More MenuMaintenance Timer Setup Maintenance Timer Setup ScreenMaintenance Timer Setup Time Remaining Change OIL RESET-RESET Timer ESC-EXIT this MenuSetpoints Setup ENTER-SUBMENU More Menus Setpoints Setup LO Suct PRSControl Output 1 Setup Control Output Throttle ENTER-MENU More MenuPID Setup ENTER-SUBMENU More Menus PID Setup ScreenPID 1 Setup Screen 00004Port Response Delay Port 1 Baud Rate Lube NO-FLOW Status Cycle TIME-INPUT # Prev NO-FLOW Input # 1 Setup Cycle Time SEC Total CyclesCycle Timer SEC More Menus Super User Menu Screen 28%YES Diagnostico-Digital Inputs Screen Digital Input Status =CLOSEDMust be in Test Mode ESC-CANCEL Analog Output Status AI 1 ENG SpeedPID Diagnostics ENTER-SUBMENU More Menus Communication Status Modbus RegisterENTER-EDIT More Menus Suction PID ESC-EXITRemote Mode Commands Reset and RUN/STOP CommunicationsAdditional Navigational Aids Communication PortsPort 2 USB Firmware Update Mode Power and COM Link Must be Maintained Firmware Download ScreenComm Fail Screen Invalid Configuration Press Setup to Access Download MenuConfiguration Fault Screen Modbus Protocol Glossary Terminal EmulatorAppendices Back Panel LED DescriptionHow To Order