Murphy CE-05171N manual Digital Input Status =CLOSED, Diagnostico-Digital Inputs Screen

Page 34

6.3.19 Digital Input Status

 

 

C

 

 

 

 

 

 

TM

 

 

 

 

 

 

 

 

 

 

 

DIGITAL INPUT STATUS

 

 

 

X=CLOSED

 

 

 

 

O=OPEN

 

 

1

X

0

0

X

 

X

X

0

0

8

9

0

0

0

X

 

X

X

X

X

16

17

0

0

0

0

 

0

0

0

0

24

25

0

0

0

0

 

0

0

0

0

32

▼▼

 

MORE MENUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagnostico-Digital Inputs Screen

6.3.20 Digital Output Status

C TM

DIGITAL OUTPUT STATUS

DIGITAL

OUTPUT

1

DIGITAL

OUTPUT

2

 

DIGITAL OUTPUT 3

DIGITAL OUTPUT 4

DIGITAL OUTPUT 5

___________________________________

DO 1 FLT LAMP

OFF

___________________________________

▼▲

ENTER-EDIT

 

▼ ▼

MORE MENUS

 

Diagnostic-Digital Outputs State Screen

6.3.21 Analog Input Status

 

C

TM

 

 

 

ANALOG INPUT STATUS

 

 

ANALOG INPUT 1

 

ANALOG INPUT 2

 

ANALOG INPUT 3

ANALOG INPUT 4

ANALOG INPUT 5

___________________________________

AI 1 SUCT PRS

00000

___________________________________

▼▲

 

 

▼ ▼

MORE MENUS

 

Diagnostic-Analog Inputs Screen

6.3.22 Analog Output Status

 

C

TM

 

 

 

ANALOG OUTPUT STATUS

 

 

ANALOG OUTPUT 1

 

ANALOG OUTPUT 2

 

ANALOG OUTPUT 3

ANALOG OUTPUT 4

ANALOG OUTPUT 5

___________________________________

AI 1 ENG SPEED

030.00

___________________________________

▼▲

ENTER-EDIT

 

▼ ▼

MORE MENUS

 

Diagnostic Analog-Outputs Status Screen

The user can see the state of each digital input in a table— whether it is open or closed.

For each of the devices configured as In Use, the user can see the state of each output and has the ability to Force an output for the purpose of testing. A force is associated with a timeout so that it will be automatically cancelled when return- ing to normal operation.

The user can view the raw counts of the analog inputs for troubleshooting.

The user can see the state of each output, and if in Test mode, has the ability to Force an output for the purpose of testing. Analog outputs under the control of PID or other Control Output settings cannot be forced. To force a PID controlled output, place the PID in Manual mode and operate the manual output value.

CE-05171N page 34 of 44

Image 34
Contents Centuriontm Warranty Table of Contents Communications Overview Basic Components and Key Features of the C3TM SeriesOptional Components Input/Output Types Digital Inputs DIAnalog Inputs AI Thermocouple Inputs TCMagnetic Pickup MPU Digital Outputs doC3-1-A Hazardous Area Operation Analog Outputs AOMounting the Centurion Controller Hardware Installation and WiringPower Supply Wiring Power Centurion C3-1 I/O Module Mounting the Centurion C3-3 DisplayWiring the Centurion C3-3 Display Wiring the Centurion C3-1/C3-2 TTD-98055N page 14 Features Home ESC ACK Fn Function KeyRUN Stop RUN/STOP Test Operational/Process Information Area Status AreaDisplay VER Mconfig PRO VEROperational Screens Controller VersionCooler Temperature Event History Panel ESD Panel Reset LOW Suct PressDISC. Temperature Shutdown History Panel ESDOIL PRS WTR Temp PSI Battery ENG SpeedAmbient Temperature VDCEnter Password Setup Screens and MenusENTER-ACCEPT ESC-CANCEL Digital Inputs Digital Outputs SetupAnalog Inputs Setup Digital InputAnalog Output 1 Setup Screen Analog Input 1 Setup ScreenAnalog Outputs Setup ANOUT01 ENTER-SUBMENU More Menus ESC Exit this MenuThermocouple 1 Setup Thermocouple Offset Thermocouple SetupThermocouple 1 Setup Type Offset Thermocouple00060 General Timer SetupGeneral Timer Setup Screen More MenuMaintenance Timer Setup Time Remaining Change OIL Maintenance Timer SetupMaintenance Timer Setup Screen RESET-RESET Timer ESC-EXIT this MenuControl Output 1 Setup Setpoints Setup ENTER-SUBMENU More MenusSetpoints Setup LO Suct PRS Control Output Throttle ENTER-MENU More MenuPID 1 Setup Screen PID Setup ENTER-SUBMENU More MenusPID Setup Screen 00004Port Response Delay Port 1 Baud Rate Cycle Timer SEC More Menus NO-FLOW Input # 1 Setup Cycle Time SEC Total CyclesLube NO-FLOW Status Cycle TIME-INPUT # Prev YES 28%Super User Menu Screen Diagnostico-Digital Inputs Screen Digital Input Status =CLOSEDMust be in Test Mode ESC-CANCEL Analog Output Status AI 1 ENG SpeedENTER-EDIT More Menus PID Diagnostics ENTER-SUBMENU More MenusCommunication Status Modbus Register Suction PID ESC-EXITAdditional Navigational Aids Remote Mode Commands Reset and RUN/STOPCommunications Communication PortsPort 2 USB Firmware Update Mode Power and COM Link Must be Maintained Firmware Download ScreenConfiguration Fault Screen Invalid Configuration Press Setup to Access Download MenuComm Fail Screen Modbus Protocol Glossary Terminal EmulatorAppendices Back Panel LED DescriptionHow To Order