Murphy CE-05171N Maintenance Timer Setup Screen, 00100, RESET-RESET Timer ESC-EXIT this Menu

Page 28

6.3.8 Maintenance Timer Setup

C

TM

 

 

MAINTENANCE TIMER SETUP

 

MAINTENANCE TIMER 1

MAINTENANCE TIMER 2

 

MAINTENANCE TIMER 3

 

MAINTENANCE TIMER 4

 

MAINTENANCE TIMER 5

___________________________________

CHANGE OIL

___________________________________

▼▲

ENTER-SUBMENU

▼ ▼

MORE MENUS

Maintenance Timer Setup Screen

C

TM

 

MAINTENANCE TIMER SETUP

 

TIMER DURATION

TIME REMAINING

 

___________________________________

CHANGE OIL

00100

___________________________________

▼▲

ENTER-EDIT

 

 

ESC-EXIT THIS MENU

 

 

 

 

Maint_1 Setup Screen

 

C

TM

MAINTENANCE TIMER SETUP

 

 

___________________________________

 

TIME REMAINING

 

___________________________________

 

CHANGE OIL

00091

 

___________________________________

 

▼▲

RESET-RESET TIMER

 

 

 

ESC-EXIT THIS MENU

 

 

 

 

 

 

Maint_1 Setup Screen 1

The user may access and edit the ten (10) maintenance set- tings for timer duration. The user may also access and reset all timer duration and time remaining settings. Note that while these are configured through MConfigPro, they must be man- ually initiated, or restarted, in C3-3 Display. All maintenance timer units are in hours.

CE-05171N page 28 of 44

Image 28
Contents Centuriontm Warranty Table of Contents Communications Overview Basic Components and Key Features of the C3TM SeriesOptional Components Input/Output Types Digital Inputs DIAnalog Inputs AI Thermocouple Inputs TCMagnetic Pickup MPU Digital Outputs doC3-1-A Hazardous Area Operation Analog Outputs AOHardware Installation and Wiring Power Supply Wiring Power Centurion C3-1 I/O ModuleMounting the Centurion Controller Mounting the Centurion C3-3 DisplayWiring the Centurion C3-3 Display Wiring the Centurion C3-1/C3-2 TTD-98055N page 14 Features Home ESC ACK Fn Function KeyRUN Stop RUN/STOP Test Operational/Process Information Area Status AreaMconfig PRO VER Operational ScreensDisplay VER Controller VersionEvent History Panel ESD Panel Reset LOW Suct Press DISC. TemperatureCooler Temperature Shutdown History Panel ESDBattery ENG Speed Ambient TemperatureOIL PRS WTR Temp PSI VDCEnter Password Setup Screens and MenusENTER-ACCEPT ESC-CANCEL Digital Outputs Setup Analog Inputs SetupDigital Inputs Digital InputAnalog Input 1 Setup Screen Analog Outputs Setup ANOUT01 ENTER-SUBMENU More MenusAnalog Output 1 Setup Screen ESC Exit this MenuThermocouple Setup Thermocouple 1 Setup Type OffsetThermocouple 1 Setup Thermocouple Offset ThermocoupleGeneral Timer Setup General Timer Setup Screen00060 More MenuMaintenance Timer Setup Maintenance Timer Setup ScreenMaintenance Timer Setup Time Remaining Change OIL RESET-RESET Timer ESC-EXIT this MenuSetpoints Setup ENTER-SUBMENU More Menus Setpoints Setup LO Suct PRSControl Output 1 Setup Control Output Throttle ENTER-MENU More MenuPID Setup ENTER-SUBMENU More Menus PID Setup ScreenPID 1 Setup Screen 00004Port Response Delay Port 1 Baud Rate Cycle Timer SEC More Menus NO-FLOW Input # 1 Setup Cycle Time SEC Total CyclesLube NO-FLOW Status Cycle TIME-INPUT # Prev YES 28%Super User Menu Screen Diagnostico-Digital Inputs Screen Digital Input Status =CLOSEDMust be in Test Mode ESC-CANCEL Analog Output Status AI 1 ENG SpeedPID Diagnostics ENTER-SUBMENU More Menus Communication Status Modbus RegisterENTER-EDIT More Menus Suction PID ESC-EXITRemote Mode Commands Reset and RUN/STOP CommunicationsAdditional Navigational Aids Communication PortsPort 2 USB Firmware Update Mode Power and COM Link Must be Maintained Firmware Download ScreenConfiguration Fault Screen Invalid Configuration Press Setup to Access Download MenuComm Fail Screen Modbus Protocol Glossary Terminal EmulatorAppendices Back Panel LED DescriptionHow To Order