CoolTherm

Manual / Bedienungsanleitung

3.2

Elektrische Funktionen

 

 

 

Funktionsprüfung Ventil- / Lüfterregelung

ja

nein

 

Bemerkungen:

 

 

 

 

 

.........................................................................................................................................

 

Lüfter schalten beim Türöffnen ab

ja

nein

 

Bemerkungen:

 

 

 

 

 

.........................................................................................................................................

 

Funktionsprüfung Rauchmelder

ja

nein

 

Bemerkungen:

 

 

 

 

 

.........................................................................................................................................

 

 

Funktionsprüfung Temperaturüberwachung

ja

nein

 

Bemerkungen:

 

 

 

 

 

.........................................................................................................................................

 

Funktionsprüfung autom. Türöffnung

ja

nein

 

Justierung der Elektromagnete siehe Bedienanleitung “Automatische Türöffnung / erste

 

 

Inbetriebnahme“

 

 

 

 

 

Bemerkungen:

 

 

 

 

 

.........................................................................................................................................

 

Funktionsprüfung Wassermelder

ja

nein

 

Bemerkungen:

 

 

 

 

 

.........................................................................................................................................

 

Überprüfung Fehler-/Störmeldungen

ja

nein

Bemerkungen:

.........................................................................................................................................

3.3 Thermodynamische Überprüfungen

Kondensatbildung am Wärmetauscher

ja

nein

Bemerkungen:

 

 

 

 

.........................................................................................................................................

 

Kühlwassereintritt am Wärmetauscher

 

...............

°C

 

Kühlwasseraustritt am Wärmetauscher

 

...............

°C

 

Schranktemperatur vor dem Wärmetauscher:

 

...............

°C

 

Schranktemperatur nach dem Wärmetauscher

 

°C

Kühlwassernetz entlüftet:

ja

nein

CoolTherm

01_998_330_0_k

page / Seite 80/83

Image 82
Contents Liebert XDK-WRack Enclosure With Integrated Liquid Cooling Page Manual CoolTherm Contents CoolThermSafety Work safety symbols AbstractSafety instructions Operating conditions Correct useDescription General function Principle of operation of cooling Dimensions Bottom plate with cutouts Rear FrontFront side / Seite 10/83 Useable space for server Technical data Chilled waterData overview CoolTherm Table a General dataData overview CoolTherm Table B Hydraulic Data Control PDU BoxFan control characteristic factory setting Storage and transportation Safety instruction for crane transport 680 kg 680 kgInstallation and commissioning Preparation for installation Check unit for transport damageAdjustable Feet Remove recirculation air duct transport lock Positioning the unitsChilled water connection Preparing heat exchanger for initial commissioning/ Seite 22/83 Condensed water connection Preparations for connectingHeat exchanger connection Electrical connection Automatic door opening Sealing of cabinetFunction Release of Automatic Door Opening Initial Commissioning Manual opening Manual closingTechnichal Data Servicing and maintenance General inspection on fans annuallyFan is installed in the reverse order of removal Regularly inspect the heat exchanger annuallyReplacement of Heat Exchanger Customer service, manufacturers address Dismantling and disposalAppendix Quality requirements on the water used in CoolTherm Checklist for unit installation Checked performed Completed CommentsCommissioning certificate Client/Setup siteConfiguration General dataGeneral condition Control of statusChilled water facility on site Electrical data / Documents Function checkMechanical functions Electrical functions Thermal checksWater flow rate adjusted Yes Flow rate …………. l / min CoolTherm Diagrams KW CoolTherm at 1.72m³/h chilled water flow rateControl Standard Factory Settings 25kW-CoolTherm at 3.58m³/h chilled water flow rateInhalt SeiteSicherheit Arbeitssicherheits Symbole AllgemeinSicherheitshinweis / Seite 45/83 Einsatzbedingungen Bestimmungsgemäße VerwendungBeschreibung Allgemeine Funktion Funktionsprinzip Kühlung Abmessungen Bodenplatte mit Öffnungen für Durchführungen Hinten VornFrontseite / Seite 51/83 Nutzbare Länge für Server / Einbauten Technische Daten KühlwasserDatenübersicht CoolTherm Tabelle a Allgemeine DatenDatenübersicht CoolTherm Tabelle B Hydraulische Daten Regelung CoolTherm VordersansichtKennlinie Lüfterregelung Werkseinstellung Lagerung und Transport Sicherheitshinweis für Krantransport 680 kg Montage und Inbetriebnahme Vorbereitung zur Montage Gerät auf Transportschäden überprüfenAufstellung der Geräte Einstellbare FüßeAnschluss Kühlwasser Transportsicherung der Luftumlenkung entfernenZur Ventilkontrolle Kühleranschluss Anschluss Kondensat Vorbereitung für AnschlussAnschluss Elektro Abdichtung GehäuseAutomatische Türöffnung FunktionAuslösung der Türöffnung Erste Inbetriebnahme Manuelles SchließenManuelles Öffnen Wartung und InstandhaltungTechnische Daten Allgemeine Kontrollen an Ventilatoren jährlich Lüfter austauschenAllgemeine Kontrollen am Kühler jährlich Auswechseln des WärmetauschersDemontage und Entsorgung Kundendienst, Herstelleradressen / Seite 75/83 Checkliste zur Geräteaufstellung Durchgeführte Überprüfung ErledigtKunde/Aufstellungsort InbetriebnahmeprotokollAllgemeine Angaben KonfigurationAllgemeiner Zustand ZustandskontrolleKühlwasseranlage im Objekt Elektrische Daten / Dokumente Funktionskontrolle Mechanische FunktionenElektrische Funktionen Thermodynamische ÜberprüfungenVolumenstrom …………. l / min CoolTherm Kennlinien Werkseinstellungen der Regelung Page Page Web Site Monitoring Single-Phase UPS