| 7: Line and Tunnel Settings |
|
|
|
|
| Line Settings (continued) | Description | |
| Xon Char |
| Set Xon Char to be used when Flow Control is set to Software. Prefix decimal |
|
|
| with \ or prefix hexadecimal with 0x or prefix a single control character |
|
|
| <control>. |
|
|
|
|
| Xoff Char |
| Set Xoff Char to be used when Flow Control is set to Software. Prefix decimal |
|
|
| with \ or prefix hexadecimal with 0x or prefix a single control character |
|
|
| <control>. |
|
|
|
|
| Gap Timer |
| Set the Gap Timer delay to Set the number of milliseconds to pass from the |
|
|
| last character received before the driver forwards the received serial bytes. |
|
|
| By default, the delay is four character periods at the current baud rate |
|
|
| (minimum 1 msec). |
|
|
|
|
| Threshold |
| Set the number of threshold bytes which need to be received in order for the |
|
|
| driver to forward received characters. |
|
|
|
|
|
| Table | |
|
|
|
|
| Line Command | Description | |
| Mode Settings |
|
|
| Mode | Set the Command Mode state of the Line. When in Command Mode, a CLI session | |
|
| operates exclusively on the Line. Choices are: | |
|
| Always | |
|
| User Serial String | |
|
| Disabled | |
|
| Note: In order to enable Command Mode on the Line, Tunneling on the Line must | |
|
| be Disabled (both Connect and Accept modes). Also, custom baud rates are not | |
|
| supported in Command Mode. | |
|
|
| |
| Wait Time | Enter the amount of time to wait during boot time for the Serial String. This timer | |
|
| starts right after the Signon Message has been set on the Serial Line and applies | |
|
| only if mode is “Use Serial String”. | |
|
|
| |
| Serial String | Enter the Text or Binary string of bytes that must be read on the Serial Line during | |
|
| boot time in order to enable Command Mode. It may contain a time element to | |
|
| specify a required delay in milliseconds x, formed as {x}. Applies only if mode is | |
|
| “User Serial String”. It may contain a binary character(s) of the form [x]. For | |
|
| example, use decimal [12] or hex [0xc]. | |
|
|
| |
| Echo Serial String | Select Enable or Disable for Echo Serial String. Applies only if mode is “User Serial | |
|
| String”. Select enable to echo received characters backed out on the line while | |
|
| looking for the serial string. | |
|
|
| |
| Signon Message | Enter the string of bytes to be sent to the Serial Line during boot time. It may contain | |
|
| a binary character(s) of the form [x]. For example, use decimal [12] or hex [0xc]. | |
|
|
|
|
To Configure Line Settings
Note: The following section describes the steps to view and configure Line 1 settings; these steps apply to other line instances of the device.
Using Web Manager
To configure a specific line, click Line in the menu and select Line 1
PremierWave XN User Guide | 47 |