GE 68K System manual W l f d address

Page 14

 

68K System Monitor

GE Energy Services

User's Guide

 

 

Command Input and Response, Continued

Possible Responses

By entering a command at the prompt and pressing ENTER, one of the following responses will happen.

If you enter

and

then

 

 

 

a recognized

it does not require

the system will execute the command.

command

special parameters

 

 

 

 

a recognized

required parameters

the system will execute the command.

command

are provided

 

 

 

 

a recognized

parameters are

a reminder line showing the correct

command

missing or invalid

command syntax will appear, including

 

 

required and optional parameters.

 

 

 

An Example, the EDIT Command:

an unrecognizable

--

a general error will be issued indicating

command

 

that the command was not recognized.

 

 

 

If you type:

e [/(b w l f d)] address

According to the syntax conventions:

The first field, e, must be entered as is, because it has no special characters around it.

If you press ENTER after typing just the e, the line above appears to show you the command parameter syntax.

The second field, [/(b w l f d)], because it is enclosed in [ ], is optional.

Select one of the valid switches within the parenthesis ( ) or leave it blank.

The last field, address, is required.

Entering

Commands

Regular Keyboard Input

The 68K Monitor allows editing of the command line by using regular keyboard input as well as a few special key combinations.

In addition to entering any printable ASCII character onto the command line, the following characters can be used:

 

 

This key…

performs this function

 

 

 

 

 

 

 

 

 

 

ESC

deletes all current data on the command line and returns to the first

 

 

 

 

character position. (except D20 base and CPM)

 

 

 

 

 

 

 

 

 

 

ENTER

executes any command that has been entered on the command line.

 

 

 

 

 

 

 

 

BACKSPACE

removes the last character from the end of the current command

 

 

 

 

line and moves the cursor one character position to the left.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continued on next page

 

 

 

 

 

 

 

 

 

 

SWM0023 1.00 2

General

1-4

Full Release

 

Image 14
Contents 68K System Monitor 2002, General Electric Canada Inc. All rights reserved Modification Record Users Guide Table of Contents Erase DstatEcho ETHAbout This Document OverviewPurpose and Audience of this User’s Guide Support Services and Training GEHCalgary.Support@ps.ge.com68K System Monitor Connecting and Using the 68K Monitor D20MES Connecting to the 68K MonitorMonitor D20MEACommand Input and Response Commandname parameters argumentsW l f d address Regular Keyboard Input 68K Monitor Display Error Messages Message Summary Command Grouping General System Commands Diagnostic Commands Memory Commands Process Commands Exchange Commands Breakpoint Commands Configuration Maintenance Commands 68K Monitor Commands Command / Platform Cross-Reference Platform-Specific CommandsList of Commands Monitor Commands AL Change Auto-logout TimerBaud Set Baud Rate Supported data rates, in bps, are Boot Startup Cache Control Cache CAL Calibrate KI For use by qualified programmer onlyCB Clear Breakpoint CCA Change Configuration File Attributes CCB Create Configuration Storage Block Parameters Type ccb 600000 100000 400 2 and press EnterCCF Clear Configuration File Used only when multiple storage regions are definedCF Copy File EpromCLS Clear Screen CP Change Priority Message Checksum is and should be CS Check SumCCU / Ccume Dump Memory Syntax DB Define Breakpoint Is this data accurate? Y/N Debug Debug ModeDo you wish to update the Nvram header? y/n Type df /b config.bin and press Enter DF Display File DataDHW Display Hardware Data DIR Directory D25 NvramSpecial Considerations DL Download DM Debug Mode Dstat Decompression Status Edit Memory Address = address to edit in hexadecimal notation Echo Echo Toggle EL Error Log Erase Flash Erase D20 ME / CcumeETH Ethernet Address Exit Exit Fill Memory Type f /w 200000 200400 F034 and press EnterFT Find Table HE or Help Help CCU / Ccume / D25HT Hdlc Test IMG Display Image Information JTF Jump To Flash JX Jam Exchange Type jx 304540 1 2 3 4 and press EnterKIM KI Metrics Move Memory Type m 200000 200400 200 and press EnterPB Print Breakpoint PR Profile Important points to note PRG Program Flash QC Query Configuration Storage Parameters QP Query Process All numeric data displayed is in hexadecimal notation QR Query RAM NvramQX Query Exchange Syntax RB Resume Breakpoint RP Resume Process RR Report RAM Partitions RT RAM Test Type rt /gn 510000 5100b0 25000 and press EnterSyntax RTB Return To BootROM RTC Test CCU RTC RX Request Exchange RZ Zmodem Download RZ Zmodem Download SA Serial Analyzer Buffer overflow SB Step Breakpoint SC Select Active Configuration SET Set System Parameters Very dangerous to use, only for programmersEarlier versions of the Monitor, this command was dhw SI Display System InformationSP Suspend Process This function stops the execution of tasks within the remote ST Serial Test Loop Test SX Send Exchange Type sx 304540 1 2 3 4 and press EnterSysc System Test Invoke Test Tool TxxxTR Trace Type tr /r 20 /t0 10 208000 != 12345678 and press Enter Type tr /r 20 /t0 10 208000 = 12345678 and press EnterType tr /r 20 /t0 10 208000 change and press Enter Type tr /r 20 /t1 10 00123456 and press EnterUL Upload VER Version VP Signal Process Winm WIN Metrics Index KIM