GE 68K System manual Error Messages

Page 17

68K System Monitor

User's Guide

GE Energy Services

Error Messages

Introduction

 

68K Monitor returns several general error messages resulting from input or syntax

 

 

errors in the command input, or system or test failures during execution.

 

 

These error messages are identified below:

 

 

 

 

 

 

Message

 

The most general error is an incorrect number of arguments for the command

Summary

 

defined. This error causes a display of the correct use of the specified function.

 

 

Other possible error messages are listed below:

 

 

 

 

 

 

 

This Message

is displayed when…

 

 

 

 

 

 

 

 

Application which

a process or user requests an exit command, but the

 

 

 

activated the monitor

process that called 68K Monitor is suspended or

 

 

 

has been deleted! (or

deleted.

 

 

 

suspended)

 

 

 

 

 

 

 

 

 

 

Breakpoint defined!

the specified address is already defined as a breakpoint,

 

 

 

 

the monitor will display this message when defining a

 

 

 

 

new breakpoint (DB).

 

 

 

 

 

 

 

 

Breakpoint not

a breakpoint was not encountered when attempting a

 

 

 

suspended!

resume (RB) or step (SB) breakpoint command.

 

 

 

 

 

 

 

 

Cannot post to

a send (SX) or jam (JX) exchange command encounters

 

 

 

exchange!

an error in sending the message to the specified

 

 

 

 

exchange.

 

 

 

 

 

 

 

 

Command aborted!

the user replied NO when asked to verify a Return to

 

 

 

 

BootROM (RTB) command.

 

 

 

 

 

 

 

 

Command not found!

the specified command is not located within 68K

 

 

 

 

Monitor’s command list.

 

 

 

 

 

 

 

 

FLASH invalid!

a directory (DIR) command on a FLASH default

 

 

 

 

database fails (i.e., no default database could be

 

 

 

 

detected).

 

 

 

 

 

 

 

 

Invalid ID!

the monitor cannot find the specified identification, or it

 

 

 

 

is incorrect. The ID can be a breakpoint number,

 

 

 

 

communications port, table name, or process or

 

 

 

 

exchange ID

 

 

 

 

 

 

 

 

Invalid switch!

the user does not specify the mode for the chosen

 

 

 

 

function.

 

 

 

 

 

 

 

 

No free breakpoints!

the define breakpoint (DB) command is attempted when

 

 

 

 

all available breakpoints are in use.

 

 

 

 

 

 

 

 

Numeric input error!

a numeric field contains non-numeric characters.

 

 

 

 

 

 

 

 

 

 

 

 

 

Continued on next page

 

 

 

 

 

 

 

General

 

 

SWM0023-1.00 -2

Full Release

1-7

 

Image 17
Contents 68K System Monitor 2002, General Electric Canada Inc. All rights reserved Modification Record Users Guide Table of Contents Echo DstatErase ETHOverview About This DocumentPurpose and Audience of this User’s Guide GEHCalgary.Support@ps.ge.com Support Services and Training68K System Monitor Connecting and Using the 68K Monitor Monitor Connecting to the 68K MonitorD20MES D20MEACommandname parameters arguments Command Input and Response W l f d address Regular Keyboard Input 68K Monitor Display Error Messages Message Summary Command Grouping General System Commands Diagnostic Commands Memory Commands Process Commands Exchange Commands Breakpoint Commands Configuration Maintenance Commands 68K Monitor Commands Platform-Specific Commands Command / Platform Cross-ReferenceList of Commands AL Change Auto-logout Timer Monitor CommandsBaud Set Baud Rate Supported data rates, in bps, are Boot Startup Cache Control Cache For use by qualified programmer only CAL Calibrate KICB Clear Breakpoint CCA Change Configuration File Attributes CCB Create Configuration Storage Block Type ccb 600000 100000 400 2 and press Enter ParametersUsed only when multiple storage regions are defined CCF Clear Configuration FileEprom CF Copy FileCLS Clear Screen CP Change Priority Message Checksum is and should be CS Check SumCCU / Ccume Dump Memory Syntax DB Define Breakpoint Is this data accurate? Y/N Debug Debug ModeDo you wish to update the Nvram header? y/n DF Display File Data Type df /b config.bin and press EnterDHW Display Hardware Data D25 Nvram DIR DirectorySpecial Considerations DL Download DM Debug Mode Dstat Decompression Status Edit Memory Address = address to edit in hexadecimal notation Echo Echo Toggle EL Error Log D20 ME / Ccume Erase Flash EraseETH Ethernet Address Exit Exit Type f /w 200000 200400 F034 and press Enter Fill MemoryFT Find Table CCU / Ccume / D25 HE or Help HelpHT Hdlc Test IMG Display Image Information JTF Jump To Flash Type jx 304540 1 2 3 4 and press Enter JX Jam ExchangeKIM KI Metrics Type m 200000 200400 200 and press Enter Move MemoryPB Print Breakpoint PR Profile Important points to note PRG Program Flash QC Query Configuration Storage Parameters QP Query Process All numeric data displayed is in hexadecimal notation Nvram QR Query RAMQX Query Exchange Syntax RB Resume Breakpoint RP Resume Process RR Report RAM Partitions Type rt /gn 510000 5100b0 25000 and press Enter RT RAM TestSyntax RTB Return To BootROM RTC Test CCU RTC RX Request Exchange RZ Zmodem Download RZ Zmodem Download SA Serial Analyzer Buffer overflow SB Step Breakpoint SC Select Active Configuration Very dangerous to use, only for programmers SET Set System ParametersSI Display System Information Earlier versions of the Monitor, this command was dhwSP Suspend Process This function stops the execution of tasks within the remote ST Serial Test Loop Test Type sx 304540 1 2 3 4 and press Enter SX Send ExchangeSysc System Txxx Test Invoke Test ToolTR Trace Type tr /r 20 /t0 10 208000 change and press Enter Type tr /r 20 /t0 10 208000 = 12345678 and press EnterType tr /r 20 /t0 10 208000 != 12345678 and press Enter Type tr /r 20 /t1 10 00123456 and press EnterUL Upload VER Version VP Signal Process Winm WIN Metrics Index KIM