| 68K System Monitor |
GE Energy Services | User's Guide |
|
|
E - Edit Memory
Platform
Description
Syntax
þ CPM þ D20 | þ D20 ME | þ D20/200 | þ D20/200 ME | þ D25 |
D20 Base | D20 Base | CCU Base | CCU Base |
|
Use this command to display and modify memory locations. The command does not verify memory contents after they are stored. After entering the command, it prompts you with the current contents of a memory location.
The different display and edit formats supported are:
• | bytes | − | hexadecimal format |
• | words | − | hexadecimal format |
• | − | hexadecimal format | |
• | scientific format | − | scientific format |
• | − | scientific format |
When the contents of the memory location appear, type:
•a new value to store at the location
•a hyphen
•a plus sign (+) or the ENTER key to move forward one location (CCU / D25 only)
•a period (.) to exit this function
Scientific values must subscribe to the following format: [±] mantissa [e [±] exponent]
The mantissa can contain a decimal point. This command differentiates between a negative number and a hyphen.
Below is usage and syntax information for this command
| Command Format | CPM / D20: | e [/(b w l f d)] address |
| |
|
| CCU / CCUME / D25: e [/(b w l f d)] [/x] address |
| ||
|
|
|
|
|
|
| Variables | /b | = | bytes (octets), the default mode |
|
|
| /w | = | words |
|
|
| /l | = | long words |
|
|
| /f | = |
| |
|
| /d | = |
| |
|
| /x | = | do not display existing contents of memory |
|
|
|
|
| location being edited |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Continued on next page |
SWM0023 1.00 2 | General |
Full Release | |
|