CY7C1371D
CY7C1373D
TAP AC Switching Characteristics Over the Operating Range[10, 11]
Parameter | Description | Min | Max | Unit |
|
|
|
|
|
Clock |
|
|
|
|
tTCYC | TCK Clock Cycle Time | 50 |
| ns |
tTF | TCK Clock Frequency |
| 20 | MHz |
tTH | TCK Clock HIGH time | 20 |
| ns |
tTL | TCK Clock LOW time | 20 |
| ns |
Output Times |
|
|
|
|
tTDOV | TCK Clock LOW to TDO Valid |
| 10 | ns |
tTDOX | TCK Clock LOW to TDO Invalid | 0 |
| ns |
Setup Times |
|
|
|
|
tTMSS | TMS Setup to TCK Clock Rise | 5 |
| ns |
tTDIS | TDI Setup to TCK Clock Rise | 5 |
| ns |
tCS | Capture Setup to TCK Rise | 5 |
| ns |
Hold Times |
|
|
|
|
tTMSH | TMS Hold after TCK Clock Rise | 5 |
| ns |
tTDIH | TDI Hold after Clock Rise | 5 |
| ns |
tCH | Capture Hold after Clock Rise | 5 |
| ns |
Notes:
10.tCS and tCH refer to the setup and hold time requirements of latching data from the boundary scan register.
11.Test conditions are specified using the load in TAP AC test Conditions. tR/tF = 1 ns.
Document #: | Page 14 of 29 |
[+] Feedback