Cypress CY7C1371D Maximum Ratings, Electrical Characteristics, Operating Range, Ambient Range

Page 19

CY7C1371D

CY7C1373D

Maximum Ratings

Exceeding maximum ratings may impair the useful life of the device. These user guidelines are not tested.

Storage Temperature

–65°C to +150°C

Ambient Temperature with

 

 

Power Applied

–55°C to +125°C

Supply Voltage on VDD Relative to GND

–0.5V to +4.6V

Supply Voltage on VDDQ Relative to GND

–0.5V to +VDD

DC Voltage Applied to Outputs

 

 

in Tri-State

–0.5V to VDDQ + 0.5V

Electrical Characteristics

Over the Operating Range[16, 17]

DC Input Voltage

–0.5V to VDD + 0.5V

Current into Outputs (LOW)

20 mA

Static Discharge Voltage

> 2001V

(MIL-STD-883, Method 3015)

 

Latch up Current

> 200 mA

Operating Range

 

Ambient

 

 

Range

Temperature

VDD

VDDQ

Commercial

0°C to +70°C

3.3V – 5%/+10%

2.5V – 5%

 

 

 

to VDD

Industrial

–40°C to +85°C

 

Parameter

Description

Test Conditions

Min

Max

Unit

 

 

 

 

 

 

 

VDD

Power Supply Voltage

 

 

3.135

3.6

V

VDDQ

IO Supply Voltage

for 3.3V IO

 

3.135

VDD

V

 

 

for 2.5V IO

 

2.375

2.625

V

VOH

Output HIGH Voltage

for 3.3V IO, IOH = –4.0 mA

 

2.4

 

V

 

 

for 2.5V IO, IOH = –1.0 mA

 

2.0

 

V

VOL

Output LOW Voltage

for 3.3V IO, IOL = 8.0 mA

 

 

0.4

V

 

 

for 2.5V IO, IOL = 1.0 mA

 

 

0.4

V

VIH

Input HIGH Voltage[16]

for 3.3V IO

 

2.0

VDD + 0.3V

V

 

 

for 2.5V IO

 

1.7

VDD + 0.3V

V

VIL

Input LOW Voltage[16]

for 3.3V IO

 

–0.3

0.8

V

 

 

for 2.5V IO

 

–0.3

0.7

V

IX

Input Leakage Current

GND VI VDDQ

 

–5

5

A

 

except ZZ and MODE

 

 

 

 

 

 

Input Current of MODE

Input = VSS

 

–30

 

A

 

 

Input = VDD

 

 

5

A

 

Input Current of ZZ

Input = VSS

 

–5

 

A

 

 

Input = VDD

 

 

30

A

IDD

VDD Operating Supply

VDD = Max., IOUT = 0 mA,

7.5 ns cycle, 133 MHz

 

210

mA

 

Current

f = fMAX = 1/tCYC

 

 

 

 

 

10 ns cycle, 100 MHz

 

175

mA

ISB1

Automatic CE

VDD = Max, Device Deselected,

7.5 ns cycle, 133 MHz

 

140

mA

 

Power down

VIN VIH or VIN VIL

 

 

 

 

 

10 ns cycle, 100 MHz

 

120

mA

 

Current—TTL Inputs

f = fMAX, inputs switching

 

 

 

 

ISB2

Automatic CE

VDD = Max, Device Deselected,

All speeds

 

70

mA

 

Power down

VIN 0.3V or VIN > VDD – 0.3V,

 

 

 

 

 

Current—CMOS Inputs

f = 0, inputs static

 

 

 

 

ISB3

Automatic CE

VDD = Max, Device Deselected, or

7.5 ns cycle, 133 MHz

 

130

mA

 

Power down

VIN 0.3V or VIN > VDDQ – 0.3V

 

 

 

 

 

10 ns cycle, 100 MHz

 

110

mA

 

Current—CMOS Inputs

f = fMAX, inputs switching

 

 

 

 

ISB4

Automatic CE

VDD = Max, Device Deselected,

All Speeds

 

80

mA

 

Power down

VIN VDD – 0.3V or VIN 0.3V, f =

 

 

 

 

 

Current—TTL Inputs

0, inputs static

 

 

 

 

Notes:

16.Overshoot: VIH(AC) < VDD +1.5V (Pulse width less than tCYC/2), undershoot: VIL(AC) > –2V (Pulse width less than tCYC/2).

17.TPower-up: Assumes a linear ramp from 0V to VDD(min.) within 200 ms. During this time VIH < VDD and VDDQ < VDD.

Document #: 38-05556 Rev. *F

Page 19 of 29

[+] Feedback

Image 19
Contents Cypress Semiconductor Corporation FeaturesSelection Guide Functional Description1 133 MHz 100 MHz UnitLogic Block Diagram CY7C1373D 1M x Logic Block Diagram CY7C1371D 512K xCY7C1371D Pin Configurations Pin Tqfp PinoutCY7C1373D Pin Configurations CE2 Pin Configurations Ball Fbga PinoutPin Definitions Functional Overview Single Read AccessesBurst Read Accesses Single Write AccessesLinear Burst Address Table Mode = GND Interleaved Burst Address Table Mode = Floating or VDDZZ Mode Electrical Characteristics Function CY7C1373D Partial Truth Table for Read/Write 2, 3Address Operation Used Function CY7C1371DIeee 1149.1 Serial Boundary Scan Jtag TAP Controller State Diagram TAP Controller Block DiagramTAP Instruction Set Bypass RegisterExtest Output Bus Tri-State TAP TimingOutput Times TAP AC Switching Characteristics Over the Operating Range10Setup Times Parameter Description Min Max Unit Clock3V TAP AC Test Conditions TAP DC Electrical Characteristics And Operating ConditionsParameter Description Conditions Min Max Unit Register Name Bit Size Identification Register Definitions Scan Register Sizes Identification CodesBit # Ball ID Ball BGA Boundary Scan Order 13A10 B10 P10 Ambient Range Electrical CharacteristicsMaximum Ratings Operating RangeThermal Resistance18 Capacitance18AC Test Loads and Waveforms 133 MHz 100 MHz Parameter Description Unit Min Max Switching Characteristics Over the Operating Range23Read Switching WaveformsRead/Write Waveforms25, 26 RiteStall NOP NOP, Stall and Deselect Cycles25, 26Address StallDON’T Care ZZ Mode Timing29Ordering Information Pin Thin Plastic Quad Flatpack 14 x 20 x 1.4 mm Package DiagramsBall BGA 14 x 22 x 2.4 mm Ball Fbga 13 x 15 x 1.4 mm Document History Issue Orig. Description of Change Date