Cypress CY7C67300 OTG Control Registers, Device n SOF/EOP Count Register, Vbus Pull-up Enable Bit

Page 48

CY7C67300

Device n SOF/EOP Count Register [W]

Device 1 SOF/EOP Count Register 0xC094

Device 2 SOF/EOP Count Register 0xC0B4

Table 73. Device n SOF/EOP Count Register

Bit #

15

 

14

13

12

11

 

10

9

8

Field

Reserved

 

 

 

 

Count...

 

 

Read/Write

-

 

-

R

R

R

 

R

R

R

Default

0

 

0

1

0

1

 

1

1

0

 

 

 

 

 

 

 

 

 

 

 

Bit #

7

6

5

4

 

3

2

1

0

Field

 

 

 

 

...Count

 

 

 

Read/Write

R

R

R

R

 

R

R

R

R

Default

1

1

1

0

 

0

0

0

0

 

 

 

 

 

 

 

 

 

 

Register Description

The Device n SOF/EOP Count register is written with the time expected between receiving a SOF/EOP. If the SOF/EOP counter expires before an SOF/EOP is received, an SOF/EOP Timeout Interrupt can be generated. The SOF/EOP Timeout Interrupt Enable and SOF/EOP Timeout Interrupt Flag are located in the Device n Interrupt Enable and Status registers respectively.

Set the SOF/EOP count slightly greater than the expected SOF/EOP interval. The SOF/EOP counter decrements at a 12 MHz rate. Therefore, in the case of an expected 1 ms SOF/EOP interval, the SOF/EOP count is set slightly greater than 0x2EE0.

Count (Bits [13:0])

The Count field contains the current value of the SOF/EOP down counter. At power up and reset, this value is set to 0x2EE0 and for expected 1 ms SOF/EOP intervals, this SOF/EOP count is increased slightly.

OTG Control Register [0xC098] [R/W]

Table 75. OTG Control Register

Reserved

Write all reserved bits with ’0’.

OTG Control Registers

There is one register dedicated for On-The-Go operation. This register is covered in this section and summarized in Table 74.

Table 74. OTG Register

Register Name

Address

R/W

OTG Control Register

C098H

R/W

 

 

 

Bit #

15

 

14

13

12

11

10

9

8

Field

Reserved

 

VBUS

Receive

Charge Pump

VBUS

D+

D–

 

 

 

Pull-up Enable

Disable

Enable

Discharge Enable

Pull-up Enable

Pull-up Enable

Read/Write

-

 

-

R/W

R/W

R/W

R/W

R/W

R/W

Default

0

 

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

Bit #

7

6

5

4

3

2

1

0

Field

D+

D–

 

Reserved

 

OTG Data

ID

VBUS Valid

Pull-down Enable

Pull-down Enable

 

 

 

Status

Status

Flag

Read/Write

R/W

R/W

-

-

-

R

R

R

Default

0

0

0

0

0

X

X

X

 

 

 

 

 

 

 

 

 

Register Description

The OTG Control register allows control and monitoring over the OTG port on Port1A. Note that the D± pull up and pull down bits override the setting in the USB 0 Control register for this port.

VBUS Pull-up Enable (Bit 13)

The VBUS Pull-up Enable bit enables or disables a 500 ohm pull up resistor onto OTG VBus.

1:500 ohm pull up resistor enabled

0:500 ohm pull up resistor disabled

Document #: 38-08015 Rev. *J

Page 48 of 99

[+] Feedback

Image 48
Contents EZ-Host Features CY7C67300 Block DiagramTypical Applications Introduction Functional OverviewInterface Descriptions Interface Options for External Memory Bus Pins MEM Pins USB InterfaceUSB Interface Pins Pin Name Pin Number OTG Interface Pins Pin Name Pin NumberOTG Interface External Memory Interface External Memory Interface Pins External Memory Interface Pins Pin Name Pin NumberExternal Memory Interface Block Diagrams Up to 256k x 16 External Code/Data Page ModeGeneral Purpose IO Interface Gpio Uart InterfaceI2C Eeprom Interface Serial Peripheral InterfaceHigh-Speed Serial Interface Programmable Pulse/PWM InterfaceHPI Interface Pins 3 Pin Name Pin Number HPI Interface Pins 3Host Port Interface IDE InterfaceIDE Throughput Mode IDE Interface Pins Pin Name Pin NumberCharge Pump Interface Pins Pin Name Pin Number ActualBooster Pins Crystal PinsCrystal Pins Pin Name Pin Number Booster InterfaceBoot Configuration Interface Boot Configuration InterfaceBoot Mode Operational ModesPower Savings and Reset Description Power Saving Mode DescriptionSleep Memory Map Bank Selected 0xC018 0xC01A Document # 38-08015 Rev. *JPage 15Registers Processor Control RegistersBank Register Bank Register Example Hex Value Binary ValueReserved Revision RegisterCPU Speed Definition Processor Speed Power Control Register Host/Device 2B Wake Enable BitHost/Device 2A Wake Enable Bit Host/Device 1B Wake Enable BitSleep Enable Bit Interrupt Enable Register Halt Enable BitOTG Interrupt Enable Bit SPI Interrupt Enable BitHSS Interrupt Enable Bit Mailbox Interrupt Enable BitOut Mailbox Interrupt Enable Bit Uart Interrupt Enable BitUSB Diagnostic Register Port 2B Diagnostic Enable BitPort 2A Diagnostic Enable Bit Port 1B Diagnostic Enable BitExternal Memory Registers Upper Address Enable Register 0xC038 R/W Upper Address Enable BitExtended Page n Map Register R/W Extended Page n Map RegisterTimer Registers Watchdog Timer Register Timeout Flag BitLock Enable Bit WDT Enable BitTimer n Register General USB RegistersUSB n Control Register Port B D+ Status BitMode Select Bit Port B Resistors Enable BitPort a Resistors Enable Bit EnablePort a SOF/EOP Enable Bit Reserved Preamble Enable BitUSB Host Only Registers USB Host Only Register Register Name Address Host 1/HostSync Enable Bit Host n Address Register ISO Enable BitArm Enable Bit Sequence Select BitPort Select Bit Underflow Flag BitStall Flag Bit NAK Flag BitError Flag Bit Sequence Status BitHost n PID Register W Host n PID RegisterPID Select Definition PID SelectHost n Count Result Register R Host n Count Result Register Endpoint Select BitsHost n Interrupt Enable Register Vbus Interrupt Enable BitID Interrupt Enable Bit Host n Device Address RegisterSOF/EOP Interrupt Enable Bit Port B Wake Interrupt Enable BitPort a Wake Interrupt Enable Bit Port B Connect Change Interrupt Enable BitSOF/EOP Interrupt Flag Bit Port B Wake Interrupt Flag BitPort a Wake Interrupt Flag Bit Port B Connect Change Interrupt Flag BitHost n SOF/EOP Counter Register R Host n SOF/EOP Counter RegisterHost n Frame Register R Host 1 Frame Register 0xC096 Host 2 Frame Register 0xC0B6IN/OUT Ignore Enable Bit USB Device Only RegistersDevice n Endpoint n Control Register R/W Device n Endpoint n Control RegisterStall Enable Bit NAK Interrupt Enable BitEnable Bit Direction Select BitDevice n Endpoint n Count Register R/W Device n Endpoint n Count RegisterDevice n Endpoint n Status Register R/W Device n Endpoint n Status RegisterOUT Exception Flag Bit Exception Flag BitSetup Flag Bit Sequence Flag BitDevice n Endpoint n Count Result Register R/W Device n Endpoint n Count Result RegisterDevice n Interrupt Enable Register R/W Device n Interrupt Enable Register Port Select BitDevice n Port Select Register R/W Device n Port Select RegisterSOF/EOP Timeout Interrupt Enable Bit Reset Interrupt Enable BitEP7 Interrupt Enable Bit EP6 Interrupt Enable BitEP0 Interrupt Enable Bit Device n Address Register WDevice n Address Register Device n Status Register R/WReset Interrupt Flag Bit EP7 Interrupt Flag BitEP6 Interrupt Flag Bit EP5 Interrupt Flag BitSOF/EOP Timeout Flag Bit SOF/EOP Timeout Interrupt Counter BitsEP2 Interrupt Flag Bit EP1 Interrupt Flag BitVbus Pull-up Enable Bit OTG Control RegistersDevice n SOF/EOP Count Register OTG Control Register ReservedGpio Registers Write Protect Enable Bit SAS Enable BitMode Select Definition Gpio Configuration 108 HSS Enable BitInterrupt 0 Enable Bit Interrupt 0 Polarity Select Bit ReservedGpio n Output Data Register Gpio n Input Data RegisterIDE Registers Mode Select Definition IDE Start Address Register 0xC04A R/WIDE Start Address Register IDE Interrupt Enable Bit IDE Enable BitIDE Stop Address Register IDE Control RegisterHSS Registers IDE PIO Port Registers 0xC050 0xC06F R/WHSS Registers Register Name Address Xoff Enable Bit CTS Enable BitReceive Interrupt Enable Bit HSS Control RegisterPacket Mode Select Bit Transmit Ready BitReceive Overflow Flag Bit HSS Baud Rate RegisterHSS Transmit Gap Register 0xC074 R/W HSS Transmit Gap RegisterTransmit Gap Select Bits HSS Data Register 0xC076 R/WHSS Receive Counter Register 0xC07A R/W HSS Receive Counter RegisterHSS Transmit Address Register 0xC07C R/W HSS Transmit Address RegisterHSS Transmit Counter Register 0xC07E R/W HSS Transmit Counter RegisterVbus to HPI Enable Bit HPI RegistersHPI Breakpoint Register HPI Registers Register Name Address Interrupt Routing RegisterID to HPI Enable Bit SOF/EOP2 to HPI Enable BitSOF/EOP2 to CPU Enable Bit SOF/EOP1 to HPI Enable BitSIEXmsg Register W SIE1msg Register SIE2msg RegisterSIEXmsg Register HPI Mailbox Register 0xC0C6 R/WReset2 Flag Bit HPI Status PortVbus Flag Bit ID Flag BitReset1 Flag Bit SPI RegistersDone1 Flag Bit Mailbox Out Flag Bit3Wire Enable Bit Phase Select BitMaster Active Enable Bit Master Enable BitByte Mode Bit Read Enable BitSPI Control Register SCK Strobe BitSPI Interrupt Enable Register Transmit Interrupt Enable BitTransfer Interrupt Enable Bit Fifo Error Flag BitReceive Interrupt Flag Bit Transmit Interrupt Flag BitSPI Interrupt Clear Register Transfer Interrupt Flag BitCRC Mode Definition CRCMode CRC Polynomial 1514 CRC Enable BitCRC Clear Bit SPI CRC Value Register Receive CRC BitSPI Data Register 0xC0D6 R/W SPI Data RegisterSPI Transmit Address Register 0xC0D8 R/W SPI Transmit Address RegisterSPI Transmit Count Register SPI Receive Address RegisterSPI Receive Count Register Uart Registers Uart Status Register 0xC0E2 R Uart Status RegisterReceive buffer full Receive buffer empty Uart Data Register 0xC0E4 R/WPWM Enable Bit PWM RegistersPWM Registers Register Name Address PWM Control RegisterPWM 3 Enable Bit PWM 2 Enable BitPWM 1 Enable Bit PWM 0 Enable BitPWM n Start Register R/W PWM n Start RegisterPWM n Stop Register R/W PWM n Stop RegisterPWM Cycle Count Register 0xC0FA R/W PWM Cycle Count RegisterPin Diagram Pin DescriptionsPin Descriptions Name Type D11/MOSI Mosi SPI MosiSCK SPI SCK D8/MISOGPIO29/OTGID GPIO28/TXGPIO27/RX GPIO26/CTS/PWM3Booster Power input 2.7V to Tie to Gnd for normal operationDC Characteristics Absolute Maximum RatingsOperating Conditions Crystal Requirements XTALIN, XtaloutUSB Transceiver GNDAC Timing Characteristics Reset TimingClock Timing Sram Read Cycle15 Sram Read Cycle Parameters Description Min Typical Max UnitLOW Sram Write Cycle Sram Write Cycle ParametersParameter Description Min Typical Max Unit HighI2C Eeprom Timing-Serial IO SCLSDA OUT HPI Host Port Interface Write Cycle Timing Chip Select Hold Data Access Time, from HPInRD falling HPI Host Port Interface Read Cycle TimingRead Pulse Width Read Cycle TimeHSS Byte Mode Transmit HSS Block Mode TransmitHSS Byte and Block Mode Receive IDE TimingRegister Summary Hardware CTS/RTS HandshakeRegister Summary HSS SOF/EOP CRC SOF/EOP2 Package Diagrams Ordering InformationOrdering Information Ordering Code Package Type Pb-FreeDocument History Orig. Submis Description of Change Sion DateSales, Solutions, and Legal Information Worldwide Sales and Design Support Products PSoC SolutionsUSB