Plug and Play
This monitor complies with the DDC™1, DDC2B and DDC2AB which are the Display Data Channel (DDC) standards of VESA.
When a DDC1 host system is connected, the monitor synchronizes with the V. CLK in accordance with the VESA standards and outputs the EDID (Extended Display Identification) to the data line.
When a DDC2B or DDC2AB host system is connected, the monitor automatically switches to each communication.
DDC™ is a trademark of Video Electronics Standard Association.
Use of the Tilt-Swivel
With the
15°
45°
45°
5°
Specifications
Picture tube | 0.30 mm aperture grille pitch |
| 20Ê inches measured diagonally |
| |
Viewable image size | Approx. 388 × 292 mm (w/h) |
| (15 3/8 × 11 1/2 inches) |
| 19.1” viewing image |
Resolution | Horizontal: Max. 1280 dots |
| Vertical: Max. 1024 lines |
Standard image area Approx. 373 × 280 mm (w/h) | |
| (14 3/4 × 11 1/8 inches) |
| or |
| Approx. 350 × 280 mm (w/h) |
| (13 7/8 × 11 1/8 inches) |
Deflection frequency Horizontal: 30 to 85 kHz | |
| Vertical: 48 to 150 Hz |
AC input voltage/current | |
| 100 to 120 V, 50/60 Hz, 1.7 A |
| 220 to 240 V, 50 – 60 Hz, 1.2 A |
Power consumption | Max. 150 W |
Dimensions | Approx. 472 × 493.5 × 501 mm (w/h/d) |
| (18 5/8 × 19 1/2 × 19 3/4 inches) |
Mass | Approx. 29.5 kg (65 lb 1 oz) |
Pin assignment
Video signal cable (HD15) (Male)
The cable accepts RGB video signals (0.714
1 2 3 4 5
6 7 8 9 10
11 12 13 14 15
EN
Damper Wire
Using a white background, very thin horizontal stripes on the screen are visible as shown on the illustration. These stripes are damper wires. These wires are attached to the aperture grille inside the Trinitron tube and are there to damp vibrations of the aperture grille in order to prevent them from influencing to the picture quality.
Damper wire
Approx. 8 cm
Approx. 8 cm
Pin No. | Signal | Pin No. | Signal | |
1 | Red | 8 | Blue Ground | |
2 | Green | 9 | DDC + 5V* | |
| (Composite |
|
| |
| 10 | Ground | ||
| Sync on Green) | |||
|
|
| ||
| 11 | — | ||
|
| |||
3 | Blue |
|
| |
12 | ||||
|
| |||
4 | — |
| Data (SDA)* | |
5 | DDC Ground* | 13 | H. Sync | |
|
|
|
| |
6 | Red Ground | 14 | V. Sync | |
|
|
|
| |
7 | Green Ground | 15 | Data Clock (SCL)* |
*Display Data Channel (DDC) Standard by VESA.
Design and specifications are subject to change without notice.
9