Cisco Systems 11.0 BT manual Show tn3270-server pu Field Descriptions, State pu-state

Page 46

show extended channel tn3270-server pu

Table 9 describes significant fields in the display.

Table 9 Show tn3270-server pu Field Descriptions

Field

Description

NAME pu-name

Name of the PU as configured.

 

 

IP:TCP ip-addr:tcpport

IP address and TCP port number configured for the PU.

 

 

XID number

Configured XID - idblk and idnum.

 

 

STATE pu-state

Possible state values and their meanings are:

 

shut—The PU is configured, but is in a shut state.

 

reset—The link station of this PU is not active.

 

test—PU is sending a TEST to establish link.

 

xid—TEST is responded, XID is sent.

 

p-actpu—The link station is up, but no ACTPU is received.

 

active—ACTPU is received and acknowledged positively.

 

act/busy—Awaiting host to acknowledge the SSCP-PU data.

 

wait—Waiting for PU status from CIP.

 

unknown—Direct PU is in an undefined state.

 

p-rqactpu-r—PU is pending a request ACTPU response.

 

p-active—DLUR PU and direct PU states disagree.

 

p-dactpu—PU is pending DACTPU.

 

dlur???—DLUR PU is in undefined state.

 

 

LINK type

LINK type is either internal adapter type and internal adapter

 

number or dlur if it is a SNA session switch PU.

 

 

 

DESTINATION mac-address or If a direct PU, then it is the destination MAC address, otherwise, it

PU-name

is the name of the partner PU.

R-LSAPnumber number

Remote and local SAP values.

 

 

IDLE-TIME number

Configured idle-time for this PU.

 

 

KEEPALIVE number

Configured keepalive for this PU.

 

 

UNBIND-ACT type

Configured unbind action for LUs on this PU.

 

 

GENERIC-POOL type

Configured generic-pool for LUs on this PU.

 

 

BYTES IN/OUT

Total number of bytes sent to/received from the host for this PU.

number/number

 

 

 

FRAMES IN/OUT

Total number of frames sent to/received from the host for this PU.

number/number

 

 

 

NEGRSP IN/OUT

Total number of SNA negative responses sent to/received from the

number/number

host.

 

 

ACTLUS number

Total number of ACTLUs received from the host.

 

 

DACTLUS number

Total number of DACTLUs received from the host.

 

 

BINDS number

Total number of BINDs received from the host.

 

 

LU number

LOCADDR of the LU.

 

 

NAME lu-name

Name of the TN3270 LU.

 

 

46TN3270 Server Commands

Image 46
Contents January 15 Release Note IntroductionIntroduction Platform Support Boot ROM RequirementsCIP Boot Image Requirements Cisco IOS PackagingUpdate to Configuration Guide Microcode Software New Software Features in 11.010BTConfiguring TN3270 Server on the Channel Interface Processor Dynamic LU Allocation Configuring TN3270 on a Channel Interface ProcessorConfiguring TN3270 on a Channel Interface Processor Formation of LU Model Type and NumberExamples of Model String Mapping Specific LU AllocationString from client Ascii Requested? String to Host Ebcdic Direct PU Configuration in Router Adapte Comman Name SNA Session Switch-End Node DlurMultiple Hosts Support IP-address Type NumberIDBLK=05D Task Command TN3270 Configuration ModesTN3270 Configuration Modes TN3270 Server Configuration Mode Dlur Configuration ModePU Configuration Mode Dlur SAP Configuration ModeCommands Allowed in Multiple Modes Task List for Multiple Appn Hosts TN3270 Configuration Task ListTN3270 Configuration Task List Task List for Non-APPN HostsConfigure TN3270 Server Configure PU Parameters on the TN3270 ServerConfigure Dlur TN3270 Configuration Task List CommandConfigure SAPs under Dlur Monitor the TN3270 Server Configure PUs under DlurPu pu-name idblk-idnum ip-address TN3270 Configuration Example Configuration dialog to configure the TN3270 function followsSYD.TN3020 SYD.VMG Update to Command Reference Update to Command ReferenceDlur DlurDlus-backup Dlus-backupGeneric-pool Generic-poolFollowing command permits generic LU pool use Idle-time Idle-timeKeepalive KeepaliveLink LinkLsap token-adapter Link Host rmac 4000.0000.0001 rsap Internal adapter type on the CIP card, which corresponds to LsapLsap 4. It must be unique within the internal adapter in that noRelated Commands Maximum-lus Maximum-lusPreferred-nnserver Preferred-nnserverHosts are in which domains and does not enforce the unique Pu directPu direct PUs may use the same value on the internal adapter as longDefaults When a specific LU name request is needed. The format can34 TN3270 Server Commands Pu Dlur Pu DlurThis value must match the idblk-idnum value defined at Show tn3270-server Field Descriptions Show extended channel tn3270-serverShow extended channel tn3270-server LU numberDlur fq-cpname Fail numberNumber Dlus fq-dlusname38 TN3270 Server Commands Show extended channel tn3270-server client-ip-address Show extended channel tn3270-server client-ip-addressLU lu-name Show tn3270-server client-ip-address Field DescriptionsLU locaddr Ip-addrtcpport State lu-stateNumber/number Show extended channel tn3270-server dlur Show extended channel tn3270-server dlurShow tn3270-server dlur Field Descriptions VRN fq-name Show tn3270-server dlurlink Field Descriptions Show extended channel tn3270-server dlurlinkShow extended channel tn3270-server dlurlink TGN tg-numberShow extended channel tn3270-server pu Show extended channel tn3270-server puShow tn3270-server pu Field Descriptions State pu-stateLU states and their meanings are Show extended channel tn3270-server pu lu Show extended channel tn3270-server pu luShow tn3270-server pu lu Field Descriptions 50 TN3270 Server Commands Shutdown ShutdownTcp-port Tcp-portTiming-mark Timing-markTn3270-server Tn3270-serverUnbind-action Unbind-actionVrn VrnCisco Connection Documentation Cisco Connection OnlineCisco Connection Online Cisco Connection Documentation