Error Code | Message Information |
|
HWC5031 | Message | IO module <number> is offline. |
| ||
| Details | The CMC has powered off the IOM. |
| Action | If the issue persists, see Getting Help. |
HWC5032 | Message | A fabric mismatch detected on IO module <number>. |
| ||
| Details | The fabric type for IOM's on the same chassis fabric must |
|
| match. |
| Action | Check chassis fabric type in CMC GUI and compare to the |
|
| type of both IOM's. |
HWC5034 | Message | A link tuning failure detected on IO module <number>. |
| ||
| Details | Link tuning table not supported for this IO modular. |
| Action | Update the CMC firmware. If the issue persists, see Getting |
|
| Help. |
HWC5036 | Message | A failure is detected on IO module <number>. |
| ||
| Details | The IOM module performance may be impacted. |
| Action | If the issue persists, see Getting Help. |
HWC6000 | Message | The <name> controller is offline. |
| ||
| Details | Information and status from the controller is unavailable. |
| Action | Remove and reapply input power. If the issue persists, see |
|
| Getting Help. |
HWC6002 | Message | The <name> controller is stuck in boot mode. |
| ||
| Details | Information and status from the controller is unavailable. |
| Action | Remove and reapply input power. If the issue persists, see |
|
| Getting Help. |
HWC6003 | Message | The <name> controller is booting. |
| ||
HWC6004 | Message | Cannot communicate with <name> controller. |
| ||
| Details | Information and status from the controller is unavailable. |
103