Error Code | Message Information |
|
| Action | Verify the input source is attached to the power supply. |
|
| Verify the input power is within the operating requirements |
|
| for the power supply. |
PSU0005 | Message | The power input for power supply <number> is outside of |
| ||
|
| the allowable range, but it is attached to the system. |
| Details | The operating requirements for the power supply may be |
|
| found in this manual or on the power supply itself. |
| Action | Verify the input power is within the operating requirements |
|
| for the power supply. |
PSU0006 | Message | Power supply <number> type mismatch. |
| ||
| LCD Message | Power supply <number> is incorrectly configured. Check |
|
| PSU. |
| Details | Power supplies should be of the same input type and power |
|
| rating. |
| Action | Install matched power supplies and review proper |
|
| configuration in this manual. |
PSU0007 | Message | Power supply <number> is operating at 110 volts, and could |
| ||
|
| cause a circuit breaker fault. |
| Details | A power supply that is designed to operate at 220V, but is |
|
| connected to a 110V power source requires additional |
|
| current for operation. The additional current may trip circuit- |
|
| breakers or cause other electrical issues with the input |
|
| source. |
| Action | Check input power source and cabling. Use recommended |
|
| input power. Review this Manual. If the issue persists, see |
|
| Getting Help. |
PSU0008 | Message | Power supply <number> voltage rating does not match the |
| ||
|
| system's requirements. |
| Details | The system does not support mixed voltage power supplies. |
| Action | Install a power supply with the correct voltage rating. |
PSU0016 | Message | Power supply <number> is absent. |
| ||
| LCD Message | PSU <number> is absent. Check PSU. |
| Details | The supply has been removed or has failed. |
123