Error Code | Message Information |
|
| Details | The memory may not be seated correctly, misconfigured, or |
|
| has failed. |
| Action | Check the memory configuration. |
|
| modules. If the issue persists, see Getting Help. |
MEM7002 | Message | A hardware mismatch detected for memory riser. |
| ||
| LCD Message | Memory riser mismatch detected. Check memory riser. |
| Details | Memory riser is installed incorrectly, or failed. |
| Action | Check that the memory riser is installed correctly. If the issue |
|
| persists, see Getting Help. |
MEM8000 | Message | Correctable memory error logging disabled for a memory |
| ||
|
| device at location <location>. |
| LCD Message | SBE log disabled on <location>. |
| Details | Errors are being corrected but no longer logged. |
| Action | Review system logs for memory exceptions. reinstall |
|
| memory at location <location>. |
OSE0000 | Message | A critical stop occurred during OS load. |
| ||
| Details | The system halted due to an exception during operating |
|
| system load or operating system initialization. |
| Action | Review operating system logs and system video for |
|
| additional information. |
OSE0001 | Message | A runtime critical stop occurred. |
| ||
| Details | The system halted due to an exception while the operating |
|
| system was running. This is a kernel panic or bug check |
|
| event. |
| Action | Review operating system logs and system video for |
|
| additional information. |
OSE0004 | Message | A soft |
| ||
| Details | A separate exception or status condition shutdown the |
|
| operating system. (IPMI sensor type 20h - offset 04h). |
| Action | Review system event log for platform events capable of |
|
| shutting the system down. |