Error Code | Message Information |
|
MEM1016 | Message | Memory device at location <location> is not installed |
| ||
|
| correctly. |
| LCD Message | Memory <location> is not installed correctly. Reinstall. |
| Details | The memory may not be seated correctly, misconfigured, or |
|
| has failed. Memory size is reduced. |
| Action | Check the memory configuration. |
|
| modules. If the issue persists, see Getting Help. |
MEM1205 | Message | Memory mirror redundancy is lost. Check memory device at |
| ||
|
| location(s) <location>. |
| LCD Message | Memory mirror lost on <location>. Power cycle system. |
| Details | The memory may not be seated correctly, misconfigured, or |
|
| has failed. |
| Action | Check the memory configuration. |
|
| modules. If the issue persists, see Getting Help. |
MEM1206 | Message | Memory mirror redundancy is degraded. Check memory |
| ||
|
| device at location <location>. |
| Details | The memory may not be seated correctly, misconfigured, or |
|
| has failed. |
| Action | Check the memory configuration. |
|
| modules. If the issue persists, see Getting Help. |
MEM1208 | Message | Memory spare redundancy is lost. Check memory device at |
| ||
|
| location <location>. |
| LCD Message | Memory spare lost on <location>. Power cycle system. |
| Details | Memory sparing is no longer available. |
| Action | |
|
| Getting Help. |
MEM1212 | Message | Memory redundancy is lost. |
| ||
| Details | The memory may not be seated correctly, misconfigured, or |
|
| has failed. |
| Action | Review system logs for memory exceptions. reinstall |
|
| memory at location <location> |
MEM1214 | Message | Memory redundancy is degraded. |
|