Error Code | Message Information |
|
| Details | FlexAddress is not implemented in one of the versions of |
|
| firmware. Please update the firmware. |
| Action | Check firmware versions. Update CMC 1 and CMC 2 |
|
| firmware to match. |
SWC5001 | Message | <name> upgrade failed. |
| ||
| Action | Reboot the system and attempt the upgrade again. |
TMP0100 | Message | The system board <name> temperature is less than the lower |
| ||
|
| warning threshold. |
| LCD Message | System board <name> temperature is outside of range. |
| Details | Ambient air temperature is too cool. |
| Action | Check the system operating environment. |
TMP0101 | Message | The system board <name> temperature is less than the lower |
| ||
|
| critical threshold. |
| LCD Message | System board <name> temperature is outside of range. |
| Details | Ambient air temperature is too cool. |
| Action | Check the system operating environment. |
TMP0102 | Message | The system board <name> temperature is greater than the |
| ||
|
| upper warning threshold |
| LCD Message | System board <name> temperature is outside of range. |
| Details | Ambient air temperature is too warm or one or more fans |
|
| may have failed. |
| Action | The system board <name> temperature is outside of the |
|
| optimum range. Check the fans. |
TMP0103 | Message | The system board <name> temperature is greater than the |
| ||
|
| upper critical threshold. |
| LCD Message | System board <name> temperature is outside of range. |
| Details | Ambient air temperature is too warm or one or more fans |
|
| may have failed. |
| Action | The system board <name> temperature is outside of the |
|
| optimum range. Check the fans. |
137