Error Code | Message Information |
|
| Action | If unintended, verify drive installation. Remove and |
|
| the indicated disk. If the issue persists, see Getting Help. |
PDR1001 | Message | Fault detected on drive <number> in disk drive bay <bay>. |
| ||
| LCD Message | Fault detected on drive <number> in disk drive bay <bay>. |
|
| Check drive. |
| Details | The controller detected a failure on the disk and has taken |
|
| the disk offline. |
| Action | |
|
| Help. |
PDR1002 | Message | A predictive failure detected on drive <number> in disk drive |
| ||
|
| bay<bay>. |
| Details | The controller received a SMART error from the drive. The |
|
| drive is operational but needs replacement. |
| Action | The drive will need replacement at the next service window. |
PDR1016 | Message | Drive <number> is removed from disk drive bay <bay>. |
| ||
| LCD Message | Drive <number> removed from disk drive bay <bay>. Check |
|
| drive. |
| Details | The controller detected that the drive was removed. |
| Action | Verify drive installation. |
|
| persists, see Getting Help. |
PDR1024 | Message | Drive mismatch detected for drive <number> in disk drive |
| ||
|
| bay <bay>. |
| LCD Message | Drive mismatch detected for drive <number> in bay <bay>. |
|
| Install correct drive type. |
| Details | The installed disk does not meet the array requirements, for |
|
| example a SATA disk may not operate in an array containing |
|
| SAS drives. |
| Action | Verify that the disk meets the array requirements. |
PST0128 | Message | No memory is detected. |
| ||
| LCD Message | No memory is detected. Inspect memory devices. |
| Details | System BIOS was unable to detect memory in the system . |
117