Error Code | Message Information |
|
| Action | Check presence, reinstall or reconnect, then reattempt the |
|
| update. If the issue persists, see Getting Help. |
HWC4015 | Message | Link Tuning error detected. |
| ||
| Details | CMC has old firmware. After updating the firmware the CMC |
|
| will recognize the device. |
| Action | Update the CMC firmware. If the issue persists, see Getting |
|
| Help. |
HWC5001 | Message | <name> is offline. |
| ||
| Action | If unexpected, check presence, then reinstall or reconnect. |
HWC5002 | Message | A fabric mismatch detected on <name>. |
| ||
| Details | The fabric type for the IOM and mezzanine cards must |
|
| match. |
| Action | Check chassis fabric type in CMC GUI and compare to the |
|
| type of IOM or mezzanine card. |
HWC5004 | Message | A link tuning failure detected on <name>. |
| ||
| Details | CMC has old firmware. After updating the firmware the CMC |
|
| will recognize the device. |
| Action | Update the CMC firmware. If the issue persists, see Getting |
|
| Help. |
HWC5006 | Message | A failure is detected on <name>. |
| ||
| Action | If the issue persists, see Getting Help. |
HWC5008 | Message | Console is not available for the <name>. |
| ||
| Action | If the issue persists, see Getting Help. |
HWC5010 | Message | <name> cannot detect any hosts. |
| ||
| Action | If the issue persists, see Getting Help. |
HWC5014 | Message | <name> is not functional and is powered off. |
| ||
| Action | If the issue persists, see Getting Help. |