Error Code | Message Information |
|
|
VLT0102 | Message | Processor module <name> voltage is greater than the upper | |
| |||
|
| warning threshold. | |
| LCD Message | Processor module <name> voltage is outside of range. | |
| Details | System hardware detected an over voltage or under voltage | |
|
| condition. | |
|
| If multiple voltage exceptions occur consecutively the | |
|
| system may power down in | |
| Action | 1. | Review system logs for power supply exceptions. |
|
| ||
|
| 2. | Remove the processor module. Inspect processor |
|
|
| socket for bent pins. |
|
| 3. | If the issue persists, see Getting Help. |
VLT0103 | Message | Processor module <name> voltage is greater than the upper | |
| |||
|
| critical threshold. | |
| LCD Message | Processor module <name> voltage is outside of range. | |
| Details | System hardware detected an over voltage or under voltage | |
|
| condition. | |
|
| If multiple voltage exceptions occur consecutively the | |
|
| system may power down in | |
| Action | 1. | Review system logs for power supply exceptions. |
|
| ||
|
| 2. | Remove the processor module. Inspect processor |
|
|
| socket for bent pins. |
|
| 3. | If the issue persists, see Getting Help. |
VLT0104 | Message | Processor module <name> voltage is outside of the | |
| |||
|
| allowable range. | |
| LCD Message | Processor module <name> voltage is outside of range. | |
| Details | System hardware detected an over voltage or under voltage | |
|
| condition. | |
|
| If multiple voltage exceptions occur consecutively the | |
|
| system may power down in | |
| Action | 1. | Review system logs for power supply exceptions. |
|
| ||
|
| 2. | Remove the processor module. Inspect processor |
|
|
| socket for bent pins. |
|
| 3. | If the issue persists, see Getting Help. |
143