Avaya DXX-1015-01 manual Configuration Parameters, Sheet 3

Page 39

 

Configuration Parameters

 

 

 

 

 

 

Label

Description

 

 

 

 

DUStore

Enables the use of the DUStore Server. Check the check box to enable or uncheck to

(dustore)

disable.

 

 

 

DUStore ADU Batch Size

The maximum number of ADUs that are sent to the DUStore Server in one set. The

(maxkills)

minimum is 1 and the default is 60.

 

 

 

Poll Wait

Sets the interval for the Toolkit's Select() method, in hundredths of a second.

(pollwait)

 

 

 

 

The default value is 5 (50 milliseconds). Low values increase CPU utilization. High

 

values (over 100) may affect the accuracy of the scaninterval parameter.

 

 

 

Maximum number of

Determines the number of revisions of a value that are kept for access with the

Revisions

GetValuesHistory() method. The default is 4, which is generally recommended.

(maxkeptrevisions)

 

 

 

 

 

 

Number of Cached Adu

Determines the maximum number of events to be kept in memory for each ADU. The

events

default is 256. A setting of 64 is recommended as a reasonable number of events to

(keepevents)

be kept in memory. High values may increase Eventsink throughput. Low values may

 

conserve memory.

 

 

 

Retry Interval

Specifies the number of seconds to wait between automatic attempts to reassign to

(serverretryinterval)

servers. The minimum is 6 seconds, maximum is 48 hours, default is 1 minute.

 

Setting this value below 30 seconds in a production environment is not

 

recommended, as it does a synchronous DS call for a list of ADU Servers and

 

attempts an asynchronous Assign to any of them it isn't already assigned to. If the

 

Assign fails (the request function itself fails), the offending ADU Server is removed

 

from the list and not retried automatically. The retry is only attempted if the Assign

 

callback reveals an error or a ServerFailed event arrives.

 

 

 

Reset Interval

Specifies the number of seconds to wait between attempts to reassign to servers

(serverresetinterval)

after receiving an ADU.FailADUCon alarm. The minimum is 0, maximum is 48 hours,

 

default is 2 seconds.

 

 

 

 

Data Element Names

 

 

 

 

 

 

Suspend Interval

Number of seconds before an ADU, which is suspended by use of the Suspend

(suspendinterval)

method by all users, is considered for Suspension. This parameter can be overridden

 

by a higher value in the Suspend method. The minimum is 1, maximum is 20 minutes,

 

default is 1 second.

 

 

 

Adu Data Percent

The percentage of ADUs that are sent to the ADU data feed, used for random

(adudata.perecnt)

sampling. The minimum is 0, maximum is 100, default is 0.

 

 

 

Find Create to Search

Enables a WAN wide DUStore search on the FindOrCreate method. Check the check

(findcreatestoresearch)

box to enable or uncheck to disable.

 

 

 

DUindex Lookup1

The name of one of the fields used to index the ADU in the DUStore Server. Used

(duindex.lookup1)

with the Find method.

 

 

 

DUindex Lookup2

The name of one of the fields used to index the ADU in the DUStore Server. Used

(duindex.lookup2)

with the Find method.

 

 

 

DUindex Info1

The name of one of the fields used to identify the ADU in the DUStore Server. Used

(duindex.info1)

with the Find method.

 

 

 

(Sheet 3 of 4)

 

 

 

 

 

Issue 1.0 June 2002 39

Image 39
Contents Avaya Interaction Center Acknowledgment Contents Agent Data Unit Server Programmer’s Guide ContentsFont Type Meaning Before YOU BeginTypographical Conventions Contacting Technical SupportProduct Documentation Readme FileElectronic Documentation Printed Documentation Educational ServicesEducational Services Issue 1.0 June 2002Agent Data Unit Server Programmer’s Guide Start-up Procedures Chapter ADU ServerOverview ADU Server Cooperation of ADU ServersADU Creation Chapter Agent Data UnitDefinition of an ADU ADU LifecycleListing Active ADUs ADU TerminationAgent Data Unit Aduid Bytes Example Description ContentsAduid ADU Data TableADU Contents ADU Contents Core ADU FieldsField Name Description Set By Agent ADU Fields Description Set BySheet 1 Sheet 2 Sheet 3 Voice Data Containers Sheet 4Value Explanation Following ADU fields are used by queues on Avaya IC Queue ADU FieldsContainers ContainersContainer Names and Special Tokens Limitations of Container Syntax Containername .!loginidADU.Create VDU.Create Container ConfigurationsParameter Type Default Description ADU.Update VDU.UpdateEDU Values written if tscon is set to true Agent Data Unit Chapter Event Monitoring ADU Event MonitoringDescription Message Event Monitoring Starting and Stopping Event MonitoringSetting Event Monitoring Criteria Setting Event Monitoring CriteriaMonitoring Criteria Syntax Example ADU.Assign loginid=Joe & ts.1.s=wrapup Relational Operators Symbol Definition DescriptionBoolean Operators Monitoring Criteria WildcardsWildcard Definition Example Criteria Example Description Monitoring Criteria ExamplesEvent Monitoring Agent Data Unit Server Programmer’s Guide Priority Description Cause/Recommended Action Chapter AlarmsAlarms ADU Server Alias Name Chapter ADU Server ConfigurationConfiguration Parameters System ConsiderationsADU Server Configuration Configuration Parameters Sheet 4 Name Description Set them on the Config tab of the ADU Server Editor dialogADU Server Configuration Chapter IDL Specification IDL Specification Chapter ADU Server Methods Method ObjectivesException Information Routing Requests Method OverviewADU Server Methods Method Overview Methods ADU.AssignADU.Create ADU.Deassign ADU.DeleteOneValueADU.Deassign ADU.DeleteValues ADU.DeleteSubTreeADU.EventsIn ADU.FindADU.EventsIn Locate an ADU having a key containing ADU.FindByKeyADU.FindOrCreate ADU.FindOrCreateADU.ForceTerminate ADU.ForwardEventADU.GetOneValue ADU.GetActiveADU.GetSomeValues ADU.GetSubTreeADU.GetSomeValues ADU.GetValueHistory ADU.GetValuesADU.GetValuesHistory ADU.GetValuesHistoryFirst value that was set was truth ADU.IncrValue ADU.MonitorADU.IncrValue ADU.SetAndTerminate ADU.RemoteWatcherADU.SetDefaultHistoryFilter ADU.SetAndTransferADU.SetAndTransfer Hsnostart Hsnochange Hsnotransfer Hsnouser Hsnodelete ADU.SetHistoryFilterADU.SetOneValue ADU.SetOneValueADU.SetValuesExtended ADU.SetValuesADU.Suspend ADU.TerminateADU.Suspend ADU.Touch ADU.TerminateMineADU.Transfer ADU.TransferADU Server Methods Agent Data Unit Server Programmer’s Guide Index SymbolsAduid IndexIssue 1.0 June 2002 Index Index Index Agent Data Unit Server Programmer’s Guide