Eicon Networks DIVA T/A ISDN Modem manual AT Command Result Codes

Page 63

AT Command Result Codes

This section provides the result codes, also known as status messages, that are displayed after an AT command is issued.

Result codes can be displayed as a word message (long-form English) or as a number code (short-form numeric response). Word messages are preceded and terminated by the sequence <CR> <LF>. Numeric codes are terminated by <CR> only. The Result Code Format command (ATVn) determines short- or long-form usage.

General Purpose Codes

Some number codes can be associated with more than one text string, depending on the format selected by ATXn.

Code

Word Message(s)

Description

0

OK

The DIVA T/A has successfully executed your command

 

 

 

2

RING

Incoming ringing is detected on the line

 

 

 

 

RING

Calling number displayed

 

FROM: Calling

 

 

 

 

 

RING(cip) called;calling

Called, and calling number displayed

 

 

 

3

NO CARRIER

Attempt to establish a connection failed

 

 

Connection ended

 

 

 

4

ERROR

Syntax of command is incorrect

 

 

Unable to execute command

 

 

Command does not exist

 

 

Entered command is outside permitted range

 

 

 

+F4

+FCERROR

 

 

 

 

6

NO DIALTONE

ISDN not initialized

 

NO CARRIER

 

 

 

 

7

BUSY

Remote user busy

 

NO CARRIER

 

 

 

 

8

NO ANSWER

Remote user not responding

 

 

 

33

FAX

Fax call

 

 

 

35

DATA

Data call

 

 

 

AT Result Codes - Connection Indicators

The following codes give you information about your connection. The word “CONNECT” in a message can relate to either DCE speed or DTE speed, depending on the selection made with ATXn. The word “CARRIER” always relates to DCE speed.

DIVA T/A ISDN Modem Reference Guide Page 63

Image 63
Contents Diva T/A Isdn Modem Reference Guide Eight Edition July 206-193-08 Contents Diva T/A Isdn Modem Reference Guide What is ISDN?What is ISDN? Channel Isdn Communication ChannelsChannel Basic Rate Access Connecting to Isdn BRI and PRIWhat is Multilink PPP? What is BACP/BOD? What is DBA? What is Always On / Dynamic Isdn AO/DI? What is Data Compression? Locating AT Commands Locating AT Commands AT Command Groups Alphabetical List of Supported AT Commands Alphabetical List of Supported AT Commands AT! CommandsAlphabetical List of Supported AT Commands AT% Commands AT& Commands AT* Commands AT Commands AT@ Commands Other AT Commands Registers AT$ Utility Commands Mini-monitor Commands General AT Commands General AT Commands Isdn Configuration Commands DefaultsValues for n Isdn Configuration Commands AT!D3=n None defaultDefault1 INS-Net64, NI-1, or 5ESS, µ law will be used defaultAT!N3=n Default null string this is an optional valueAT!N2=n Number. Numbers are separated by a semicolonFor more details, refer to the Rvscom documentation AT!X56=nOn region 255 do not attempt 56k data call retry COM Port Configuration Commands Ring COM Port Configuration CommandsUpon connection, the Diva T/A reports the DCE speed For example, ConnectCall Control Commands ATA Call Control CommandsATH Configuration Commands Configuration Commands AT!V0=n Use the default settingsProfile Commands Multilink PPP Commands Multilink PPP Commands Endpoint Discriminator Class/Address AT%M3=b3c665ac11Internet Protocol IP Always On / Dynamic Isdn AT Commands Always On / Dynamic Isdn AT Commands AT!X14=n AT!X13=n when Bacp is disabled, seeWill be opened after the delay specified by AT!X10 Default 1000 bytesDefined as follows Default values for each setting, and is defined as followsDefault AT!X22=n AT!X18AT!X26=n Default CF PPP overAT!X25=n Connection numbers affects the range ofAT!X21. SeeAT!X21Utility Commands Start or Display the Result of a PPP trace Utility CommandsInternal TA access command reserved for VU Start or display the Result of a Lapd traceEnter the monitor on the next reset Soft reset the unit and enter the monitorStart an AO/DI X.25 Trace AT? Register CommandsRegister Commands Analog Device Commands AT*Fn Analog Device CommandsEnable using same terminal endpoint identifier as data port To be disabledDisable. Recommended for modem/fax calls Enable with default values defaultMini-monitor Commands AT Command Result Codes AT Command Result Codes ConnectCarrier Connect Protocol None Protocol Transparent ModeConnect 75T/1200R Connect 1200T/75RBACP/BOD Index