Eicon Networks DIVA T/A ISDN Modem manual Multilink PPP Commands

Page 46

Multilink PPP Commands

The following table describes the MLPPP configuration commands.

AT%M1=n

Local Endpoint Discriminator Class. The value for ‘n’ specifies the Local Endpoint

 

Discriminator Class. If you specify n=1 (class 1), the Local Endpoint Discriminator

 

Address (specified with AT%M3=n) must be an even number. For a list of classes, see

 

“Endpoint Discriminator Class/Address” on page 48.

 

 

AT%M2=n

Remote Endpoint Discriminator Class. The value for ‘n’ specifies the Remote

 

Endpoint Discriminator Class. For a list of classes, see “Endpoint Discriminator

 

Class/Address” on page 48.

 

 

AT%M3=n

Local Endpoint Discriminator Address. The value for ‘n’ specifies the Local

 

Endpoint Discriminator Address. For a description of permitted addresses, see

 

“Endpoint Discriminator Class/Address” on page 48.

 

 

AT%M4=n

Remote Endpoint Discriminator Address. The value for ‘n’ specifies the Remote

 

Endpoint Discriminator Address. For a description of permitted addresses, see

 

“Endpoint Discriminator Class/Address” on page 48.

 

 

AT%P5=n

Bandwidth Allocation Control Protocol (BACP) / Bandwidth on Demand (BOD).

 

This command specifies whether BACP/BOD is enabled or disabled. When enabled,

 

the DIVA T/A will drop to one B channel (reducing costs) when throughput drops

 

below 64K. The DIVA T/A first attempts to negotiate BACP; if this is unsuccessful, the

 

DIVA T/A falls back to BOD.

 

n=0

Disable (default).

 

n=1

Enable.

 

Note: You can use this parameter only if the DIVA T/A has been configured for MLPPP.

 

 

AT%P6=n

Set Initial Billing Interval Timer. Sets the timer (in seconds) to match the amount of

 

time your ISDN provider allocates as the first time interval.

 

Note: If the value is set to 0, the timer is not used. Setting this value to 0, also

 

effectively sets AT%P7 to 0.

 

Range: 0 to 65535.

 

Default: 60 seconds.

 

 

AT%P7=n

Set Billing Interval Timer. Sets the timer (in seconds) to match the amount of time

 

your ISDN provider designates as the minimum chargeable unit for all subsequent

 

billing.

 

Note: If the value is set to 0, the timer is not used.

 

Range: 0 to 65535.

 

Default: 60 seconds.

 

 

 

DIVA T/A ISDN Modem Reference Guide Page 46

Image 46
Contents Diva T/A Isdn Modem Reference Guide Eight Edition July 206-193-08 Contents What is ISDN? Diva T/A Isdn Modem Reference GuideWhat is ISDN? Isdn Communication Channels ChannelChannel Connecting to Isdn BRI and PRI Basic Rate AccessWhat is Multilink PPP? What is BACP/BOD? What is DBA? What is Always On / Dynamic Isdn AO/DI? What is Data Compression? Locating AT Commands Locating AT Commands AT Command Groups Alphabetical List of Supported AT Commands AT! Commands Alphabetical List of Supported AT CommandsAlphabetical List of Supported AT Commands AT% Commands AT& Commands AT* Commands AT Commands AT@ Commands Other AT Commands Registers AT$ Utility Commands Mini-monitor Commands General AT Commands General AT Commands Defaults Isdn Configuration CommandsValues for n Isdn Configuration Commands INS-Net64, NI-1, or 5ESS, µ law will be used default None defaultDefault1 AT!D3=nNumber. Numbers are separated by a semicolon Default null string this is an optional valueAT!N2=n AT!N3=nAT!X56=n For more details, refer to the Rvscom documentationOn region 255 do not attempt 56k data call retry COM Port Configuration Commands COM Port Configuration Commands RingFor example, Connect Upon connection, the Diva T/A reports the DCE speedCall Control Commands Call Control Commands ATAATH Configuration Commands Configuration Commands Use the default settings AT!V0=nProfile Commands Multilink PPP Commands Multilink PPP Commands AT%M3=b3c665ac11 Endpoint Discriminator Class/AddressInternet Protocol IP Always On / Dynamic Isdn AT Commands Always On / Dynamic Isdn AT Commands Default 1000 bytes AT!X13=n when Bacp is disabled, seeWill be opened after the delay specified by AT!X10 AT!X14=nAT!X18 Default values for each setting, and is defined as followsDefault AT!X22=n Defined as followsConnection numbers affects the range ofAT!X21. SeeAT!X21 Default CF PPP overAT!X25=n AT!X26=nUtility Commands Start or display the Result of a Lapd trace Utility CommandsInternal TA access command reserved for VU Start or Display the Result of a PPP traceSoft reset the unit and enter the monitor Enter the monitor on the next resetStart an AO/DI X.25 Trace Register Commands AT?Register Commands Analog Device Commands Analog Device Commands AT*FnEnable with default values default To be disabledDisable. Recommended for modem/fax calls Enable using same terminal endpoint identifier as data portMini-monitor Commands AT Command Result Codes Connect AT Command Result CodesCarrier Connect Connect 1200T/75R Protocol Transparent ModeConnect 75T/1200R Protocol NoneIndex BACP/BOD