V.120 Configuration Commands

AT!E5=n

V.120 N200 (Maximum Retry Count). Applicable to the multiframe mode only. N200

 

(Maximum Retry Count) is a system parameter which identifies the maximum number

 

of retransmissions of a frame due to T200 expiring. When the maximum number of

 

retransmissions is reached, the recovery process is started which may cause call

 

disconnection.

 

Range: 1 to 10.

 

Default: 3.

 

 

AT!E6=n

V.120 T203 (Link Integrity Timer). Applicable to the multiframe mode only. T203 (Link

 

Integrity Timer) is the maximum time allowed without frames (including data and

 

control) being exchanged. Its purpose is to verify that the remote device is still online

 

and operational. When the Link Integrity Timer expires, recovery procedures are started

 

which may cause the disconnection of the current call.

 

The unit of measurement is seconds.

 

Range: 1 to 255.

 

Default: 30.

 

The value specified for T200 (Retransmission Timer) (see “AT!E4=n” on page 42) must

 

be less than the value specified for T203 (Link Integrity Timer). Otherwise, the default

 

values are used.

 

 

AT!E7=n

V.120 Idle Timer. Idle Timer refers to the maximum time without the exchange of data

 

frames between the local and the remote devices and before the automatic termination

 

of the connection. Its purpose is to reduce communications costs while data is not

 

being transferred for a period of time (operates in both the multiframe and

 

unacknowledgement modes). When Idle Timer expires, this immediately initiates the

 

disconnection of calls. Setting a zero value disables Idle Timer.

 

The unit of measurement is minutes.

 

Range: 0 to 10000.

 

Default: 1440 (24 hours).

 

 

DIVA T/A ISDN Modem Reference Guide Page 43

Image 43
Contents Diva T/A Isdn Modem Reference Guide Eight Edition July 206-193-08 Contents Diva T/A Isdn Modem Reference Guide What is ISDN?What is ISDN? Channel Isdn Communication ChannelsChannel Basic Rate Access Connecting to Isdn BRI and PRIWhat is Multilink PPP? What is BACP/BOD? What is DBA? What is Always On / Dynamic Isdn AO/DI? What is Data Compression? Locating AT Commands Locating AT Commands AT Command Groups Alphabetical List of Supported AT Commands Alphabetical List of Supported AT Commands AT! CommandsAlphabetical List of Supported AT Commands AT% Commands AT& Commands AT* Commands AT Commands AT@ Commands Other AT Commands Registers AT$ Utility Commands Mini-monitor Commands General AT Commands General AT Commands Defaults Isdn Configuration CommandsValues for n Isdn Configuration Commands AT!D3=n None defaultDefault1 INS-Net64, NI-1, or 5ESS, µ law will be used defaultAT!N3=n Default null string this is an optional valueAT!N2=n Number. Numbers are separated by a semicolonAT!X56=n For more details, refer to the Rvscom documentationOn region 255 do not attempt 56k data call retry COM Port Configuration Commands Ring COM Port Configuration CommandsUpon connection, the Diva T/A reports the DCE speed For example, ConnectCall Control Commands ATA Call Control CommandsATH Configuration Commands Configuration Commands AT!V0=n Use the default settingsProfile Commands Multilink PPP Commands Multilink PPP Commands AT%M3=b3c665ac11 Endpoint Discriminator Class/AddressInternet Protocol IP Always On / Dynamic Isdn AT Commands Always On / Dynamic Isdn AT Commands AT!X14=n AT!X13=n when Bacp is disabled, seeWill be opened after the delay specified by AT!X10 Default 1000 bytesDefined as follows Default values for each setting, and is defined as followsDefault AT!X22=n AT!X18AT!X26=n Default CF PPP overAT!X25=n Connection numbers affects the range ofAT!X21. SeeAT!X21Utility Commands Start or Display the Result of a PPP trace Utility CommandsInternal TA access command reserved for VU Start or display the Result of a Lapd traceSoft reset the unit and enter the monitor Enter the monitor on the next resetStart an AO/DI X.25 Trace AT? Register CommandsRegister Commands Analog Device Commands AT*Fn Analog Device CommandsEnable using same terminal endpoint identifier as data port To be disabledDisable. Recommended for modem/fax calls Enable with default values defaultMini-monitor Commands AT Command Result Codes Connect AT Command Result CodesCarrier Connect Protocol None Protocol Transparent ModeConnect 75T/1200R Connect 1200T/75RBACP/BOD Index