9.2.3. Setting the Inverter PCB, TS PCB and LCD Unit
1.Set the LCD Unit to the LCD Front Cabinet in order.
2.Attach the 2 drop holders.
3.Connect the Cable to the Connector. (CN200,CN201)
4.Connect the 3 Cables to the 3 Connectors.
5.Fix the Inverter PCB using the 2 Screws. <N5>
Screws <N5>: DRQT26+D4FKL
C
LCD Drop Holder
Connector
(CN201) Connector (CN200)
TS PCB
LCD Drop
A B Holder
LCD Unit | Inverter PCB |
<N5> |
C
B <N5>
A
LCD Front Cabinet
to Connector (CN200)
QPreparation of Inverter
* Notes:
1.Apply the load when attaching the parts. 20N to 30N (2 to 3Kgf)/cm2
2.When handling
Safety Working
|
|
| Important Parts |
|
|
| for Safety |
|
|
|
|
Do not touch the Transformer part | |||
when attaching to Inverter Case. |
|
|
|
|
| Check the part |
|
|
| number ’2148M1’ |
|
Inverter Shield Case
Prepare Inverter and the Inverter shield Case Outside for Assysite.
Inverter Shield Case Outside
Wrap Inverter Shield Tape around Inverter Shield Case and attach.
Ensure that Inverter Shield Tape does not run over the edge of Inverter Shield Case.
|
| Inverter is set, | Inverter Shield Case is set |
|
| Attach the Inverter Shield Tape | |
|
| attach |
|
| Board attachment |
|
|
|
|
|
|
|
|
|
|
<Inverter Shield Tapes Attachment Guide> Protrusion by wrinkles, etc. = 0.2 or less Air Bubble = 1 cm 2 or less / 1 bubble size
Attach it putting the protrusion mark next to the caution label.
Match the board edge and the case edge.
Difference: 0.5mm or less