· Connection
The PV generator is connected by means of the externally accessible,
Please note:
All PV generator inlets are positioned in pairs. Inlet 1 is left, inlet 2 is in the middle, and inlet 3 is right. The upper connections are «POSITIVE», and the lower ones are «NEGATIVE».
Illustr.: PV generator connection via Tyco Solarlok connectors
Important Information
!
· The DC voltage can reach up to 850 V. The device may only be opened by a
qualified electrician! |
|
|
|
· As soon as the PV generator has been | GB |
connected to the Solar Inverter by means |
|
of the DC connectors and the PV genera- |
|
tor has been switched on, the PV genera- |
|
tor voltage is applied internally! |
|
·Please note that the inlet capacitors are still live, even after the PV generator has been switched off or the PV generator connector has been pulled out!
·After the AC and DC sides have been isolated, the Solar Inverter remains live for up to approximately five minutes!
·Therefore, wait at least five minutes for the internal voltage to discharge. Prior to working on the Solar Inverter, always
113