Linking and Interconnecting Possibilities
Depending on the distance to be overcome and the number of Solar Inverters, there are the following linking possibilities:
Type of Link | Distance | Solar System with 1 | Solar System with up to 99 |
|
| Solar Inverter | Solar Inverters |
|
|
| |
Sunways | PC not more than | Connection of the PC via | Connection between the PC and |
Monitor Direct | 5 - 25 m away | USB (max 5 m) or RS232 | the Solar Inverter via USB with |
Link |
| (max. 25 m) (see 1) | the RS485 address 01 (max. 5 m) |
|
|
| (see 4) |
Sunways | PC not more than | Link between Solar | Link between Solar Inverter and |
Monitor Local | 500 m away (mi- | Inverter and PC via RS485 | PC via RS485 bus, using an inter- |
Link | nus RS485 cable | bus, using an interface | face transformer at the PC |
| length between | transformer at the PC | (see 5) |
| the Solar Inverters) | (see 2) |
|
Sunways | PC more than | Use of a remote modem | Connection of the remote |
Monitor | 500 m away | at the Solar Inverter RS232 | modem via an interface trans- |
Remote Link |
| port; link via modem at | former at the RS485 of the Solar |
|
| the PC (see 3) | Inverter with the RS485 address |
|
|
| 01, link via modem at the PC |
|
|
| (see 6) |
Sunways | Sunways Commu- | Use of an RS485 cable set | Use of an RS485 cable set |
Communicator | nicator not more | (comes with the Sunways | (comes with the Sunways |
Direct Link | than 25 m away | Communicator) | Communicator) |
|
|
|
|