Unitech MS860 manual Using BAR Codes to SET Scanner Network

Page 19

NETWORK SETTINGS

USING BAR CODES TO SET SCANNER NETWORK:

The WLAN default settings are shown below.

WLAN Default Settings:

Item

Default Setting

IP Address

192.168.1.250

IP Subnet Mask

255.255.255.0

Gateway IP Address

192.168.1.254

SSID

Wlandemo

RF Channel

6

WEP

Disabled

Authentication Type

Auto

Use the TCP/IP barcode chart on page 81 and the ASCII Chart on pages 83 to 86 to configure your scanner to your own network settings, as the example below:

SSID: MySSID

IP: 192.168.1.100

Mask: 255.255.255.0

Please follow the steps below:

 

 

 

 

 

 

 

 

 

 

Scan the Enter Group 10 bar code

 

 

 

 

 

 

 

 

Then scan: SSID Space

M

y

S

S

I

D

CR

 

 

 

 

Then scan: IP Space 1

9

2

.

1

6

8

. 1

.

1

0 0

CR

Then scan: MASK Space

2

5

5 .

2

5

5 .

2

5

5 .

0 CR

Lastly, scan: SE CR EE

 

 

 

 

 

 

 

 

 

 

 

Other than that last line, it’s pretty self-explanatory. Several parameters can be modified together in one session, as above. Or, only one parameter can be modified per session, as below. The last commands

-SE, CR, EE - are simply a sequence to end the programming mode, and along with Enter Group 10 must be included whenever program- ming network settings via bar code.

To turn DHCP on, scan the following sequence:

Scan the Enter Group 10 bar code

Then scan: DHCP

Space

1 CR

Lastly, scan: SE

CR EE

 

17

 

MS860 WiFi Manual

Image 19
Contents MS860 WiFi Bar Code Scanner Table of Contents Introduction IntroductionQuick Start Important Notes Importantscanner Ndotesaccessories Scanner LED Scanner PartsBuzzer Cradle LEDs Cradle PartsCharging the Scanner How to determine if the scanner needs rechargingNetwork Settings Modifying the WiFi settings IP Address GlossaryWEP Using SCM for Scanner Network Setting Network SettingsNetwork Settings Network Settings Network Settings Using BAR Codes to SET Scanner Network Example IP Space 192.168.1.250 CR Network Settings Example Default CR Installing Virtual COM Network Settings Start Virtual COM Network Settings Vcom should automatically create a virtual com port for Glossary ConfigureWEP the virtual com port using monitor.exe Keep the default settings of the server port and server IP Network Settings Network Settings Start It Up Scanner Configuration Manager Try It Keyboard Wedge Beeps and DelaysInterblock Delay Intercharacter DelayUse Numeric Keypad Function CodeCaps-Lock LanguageHandshaking Baud RateParity Data BitData Direction RS232BCC Character Time OutTerminator Scanner PortDouble Verification Use Code IDSettings Function Code RS232 BCC Character Scanner Port EAN-13 Label Code IV or Label Type Scanning ModePostamble Aim Function for Long Range EngineAiming Time for Long Range Engine PreambleCode Bar Code SymbologiesInterleaved 2 Standard 2 of 5 / Toshiba Code China Postal Code EAN MSI / Plessey Code UPC-A CodabarEAN-13 UPC-EDelta Code EAN-8Label Code IV Supplement Code for UPC-E, ISBN, EAN-13Qualifier Data EditingModifier Scanner Configuration Manager Everything Else Formula Arrange FormulasIntroduction Programming VIA Scanner InputBeep Quick Setup Bar CodesUPC-E Medium Interblock DelayIntercharacter Delay Beep Tone see page 40 0 NoneKeyboard Interface None Baud Rate9600 ParityData Direction for terminal wedge see Send to Host SecondDefine Code ID TerminatorEnter Code IDLabel Type Scanning ModeDouble Verification TriggerPpoo Interleaved 2 of 5 ITF see Symbologies GroupCode 39 see Check Digit Not CalculateUCC/EAN 128 see Standard 2 China Postal Code Toshiba CodeCode 32 Italian Pharmacy see TelepenDefine a Separator for Double Labels Define the EAN 128 Fields SeparatorDefine Minimum and Maximum Length Code 93 see Code 128 seeMSI / Plessey Code No Send Check Digit Double ModuleLabel Code IV and V see Code 11 Special seeCodabar see No SendExit EAN-8 EAN-13 seeOff / On Supplement Code seeDelta Distance Code see Qualifiers Special Characters ModifiersFormula Format Code TypeSpecial Characters in this section TCP/IP Function Codes for PC Characters in parentheses represent Extended Code Ascii Chart= %H ~ %S Delete %T ? %J NUL %U @ %V \ %L `%W # /C $ /D + /K Programming VIA Scanner Input SP Space Specifications Mechanical Generic Scanner Troubleshooting Tips TroubleshootingProblems and Solutions Problem No output from scanner Troubleshooting BAR Code Test Chart BAR Code Test Char