Unitech MS860 manual Example Default CR

Page 22

NETWORK SETTINGS

13. SAVE

Save the configuration settings Example: SAVE CR

14. SE

Save the configuration settings and reboot Example: SE CR

15. DEFAULT

Restore configuration settings to factory default, and automati- cally reboot the module

Example: DEFAULT CR

16. EXIT

Reboot the module without saving any configuration changes Example: EXIT CR

IMPORTANT:

Once you have completed the network configuration for the scanner, VCOM will be required to configure the virtual com port, which means the VCOM utility must run in the background. This is detailed on pages 21 to 24.

Some Access Points may not be able to re-connect the MS860 and its cradle after it’s been out of range. In this case the scan- ner will need to be powered off and powered on again, and the VCOM communication must be re-started.

VCOM Utility supports Windows2000 and XP.

Unfortunately, Windows98 and NT are not currently supported.

Before entering into Command Mode, power off the scanner and then scan “Enter Group 10” on page 81 within 5 seconds after powering the scanner back on.

MS860 WiFi Manual

20

Image 22
Contents MS860 WiFi Bar Code Scanner Table of Contents Introduction IntroductionQuick Start Important Notes Importantscanner Ndotesaccessories Scanner Parts Scanner LEDBuzzer Cradle Parts Cradle LEDsHow to determine if the scanner needs recharging Charging the ScannerNetwork Settings Modifying the WiFi settings Glossary IP AddressWEP Network Settings Using SCM for Scanner Network SettingNetwork Settings Network Settings Network Settings Using BAR Codes to SET Scanner Network Example IP Space 192.168.1.250 CR Network Settings Example Default CR Installing Virtual COM Network Settings Start Virtual COM Network Settings Vcom should automatically create a virtual com port for Glossary ConfigureWEP the virtual com port using monitor.exe Keep the default settings of the server port and server IP Network Settings Network Settings Start It Up Scanner Configuration Manager Try It Intercharacter Delay Beeps and DelaysInterblock Delay Keyboard WedgeLanguage Function CodeCaps-Lock Use Numeric KeypadData Bit Baud RateParity HandshakingTime Out RS232BCC Character Data DirectionScanner Port TerminatorUse Code ID Double VerificationSettings Function Code RS232 BCC Character Scanner Port EAN-13 Label Code IV or Scanning Mode Label TypePreamble Aim Function for Long Range EngineAiming Time for Long Range Engine PostambleBar Code Symbologies CodeInterleaved 2 Standard 2 of 5 / Toshiba Code China Postal Code EAN MSI / Plessey Code Codabar UPC-AUPC-E EAN-13EAN-8 Delta CodeSupplement Code for UPC-E, ISBN, EAN-13 Label Code IVQualifier Data EditingModifier Scanner Configuration Manager Arrange Formulas Everything Else FormulaProgramming VIA Scanner Input IntroductionQuick Setup Bar Codes BeepUPC-E Beep Tone see page 40 0 None Interblock DelayIntercharacter Delay MediumKeyboard Interface Parity Baud Rate9600 NoneSecond Data Direction for terminal wedge see Send to HostCode ID TerminatorEnter Define Code IDTrigger Scanning ModeDouble Verification Label TypePpoo Check Digit Not Calculate Symbologies GroupCode 39 see Interleaved 2 of 5 ITF seeTelepen Standard 2 China Postal Code Toshiba CodeCode 32 Italian Pharmacy see UCC/EAN 128 seeDefine a Separator for Double Labels Define the EAN 128 Fields SeparatorDefine Minimum and Maximum Length No Send Check Digit Double Module Code 128 seeMSI / Plessey Code Code 93 seeNo Send Code 11 Special seeCodabar see Label Code IV and V seeExit EAN-13 see EAN-8Off / On Supplement Code seeDelta Distance Code see Qualifiers Modifiers Special CharactersFormula Format Code TypeSpecial Characters in this section TCP/IP Function Codes for PC Ascii Chart Characters in parentheses represent Extended Code= %H ~ %S Delete %T ? %J NUL %U @ %V \ %L `%W # /C $ /D + /K Programming VIA Scanner Input SP Space Specifications Mechanical Troubleshooting Generic Scanner Troubleshooting TipsProblems and Solutions Problem No output from scanner Troubleshooting BAR Code Test Chart BAR Code Test Char