SCANNER CONFIGURATION MANAGER
Bar Code Symbologies, continued
Interleaved 2 of 5
zEnabled toggles the ability for the scanner to read I 2 of 5 on or off. Default is “Yes”.
zCode ID is a
Default is letter “I”.
zFix Length (by first 3 reads) fixes the length of acceptable subse- quent bar code reads from the first three bar codes read. Useful as a data verification if all bar codes are of a consistent length.
Default is “No”.
zCheck Digit defines whether or not a check digit (to insure data accuracy) is calculated, and if so, whether it should be sent or not. Default is “Not Calculate”.
zSupress Digit suppresses the output of the first or last bar code digit. Default is “Not Suppressed”.
zMinimum Length defines the minimum length the user will accept for a valid bar code.
Default is “10”.
zMaximum Length defines the maximum length the user will accept for a valid bar code.
Default is “64”.