SCANNER CONFIGURATION MANAGER
Bar Code Symbologies, continued
Standard 2 of 5 / Toshiba Code (China Postal Code)
zEnabled toggles the ability for the scanner to read S 2 of 5 / Toshiba Code on or off.
Default is “No”.
zS25 Code ID is a
zToshiba Code ID is the same as S25 Code ID (above) but instead applicable to Toshiba Code.
Default is letter “C”.
zFix Length (by first 3 reads) fixes the length of acceptable subse- quent bar code reads from the first three bar codes read. Useful as a data verification if all bar codes are of a consistent length.
Default is “No”.
zCheck Digit defines whether or not a check digit (to insure data accuracy) is calculated, and if so, whether it should be sent or not. Default is “Not Calculate”.
zMinimum Length defines the minimum length the user will accept for a valid bar code.
Default is “10”.
zMaximum Length defines the maximum length the user will accept for a valid bar code.
Default is “64”.
MS860 WiFi Manual | 50 |