SCANNER CONFIGURATION MANAGER

Data Editing, continued

Note:

Even if the original bar code data is not modified, if additional charac- ters are to be added (see “Add New” below) the original Start Param- eter must be defined as From Position “1” and the End Parameter defined as “All Remaining”, otherwise, none of the original data will be output.

Add New adds characters (printing and non- printing) to the data output from the MS860. These characters can be added before, after, and within the actual scanned data. Pre-defined characters include:

z<t> Tab

z<r> Carriage Return

z<n> Line Feed

z<d> Any Digit (data editing)

z<a> Any Letter (data editing)

z<*> Interblock Delay (data editing)

z<“> (quotation marks)

z<dd> Character in hexadeximal notation

z<<> < (less than)

z<>> > (greater than)

Characters must be bracketed by <> symbols.

Letters and numbers should be represented in hexadecimal format (accessable in a linked menu) to avoid confusion. For instance, the lower-case letter “t” should be entered as <74> and the numeral “5” should be entered as <35>.

Function codes (F keys, Cursor Up, Enter, etc.) can also be inserted via hexadecimal code (accessable in a linked menu).

Delete removes existing modifier strings.

 

Move Up / Move Down (pictured to the right) moves the

 

modifiers up and down in relation to each other. The top modifier

 

will be performed first and each one down the list will be per-

 

formed in sequence. The original data (modified or unmodified,

 

part or whole) will be output according to its position in the modifier

 

sequence.

58

MS860 WiFi Manual

Image 60
Contents MS860 WiFi Bar Code Scanner Table of Contents Introduction IntroductionQuick Start Important Notes Importantscanner Ndotesaccessories Scanner Parts Scanner LEDBuzzer Cradle Parts Cradle LEDsHow to determine if the scanner needs recharging Charging the ScannerNetwork Settings Modifying the WiFi settings Glossary IP AddressWEP Network Settings Using SCM for Scanner Network SettingNetwork Settings Network Settings Network Settings Using BAR Codes to SET Scanner Network Example IP Space 192.168.1.250 CR Network Settings Example Default CR Installing Virtual COM Network Settings Start Virtual COM Network Settings Vcom should automatically create a virtual com port for Glossary ConfigureWEP the virtual com port using monitor.exe Keep the default settings of the server port and server IP Network Settings Network Settings Start It Up Scanner Configuration Manager Try It Beeps and Delays Interblock DelayIntercharacter Delay Keyboard WedgeFunction Code Caps-LockLanguage Use Numeric KeypadBaud Rate ParityData Bit HandshakingRS232 BCC CharacterTime Out Data DirectionScanner Port TerminatorUse Code ID Double VerificationSettings Function Code RS232 BCC Character Scanner Port EAN-13 Label Code IV or Scanning Mode Label TypeAim Function for Long Range Engine Aiming Time for Long Range EnginePreamble PostambleBar Code Symbologies CodeInterleaved 2 Standard 2 of 5 / Toshiba Code China Postal Code EAN MSI / Plessey Code Codabar UPC-AUPC-E EAN-13EAN-8 Delta CodeSupplement Code for UPC-E, ISBN, EAN-13 Label Code IVData Editing QualifierModifier Scanner Configuration Manager Arrange Formulas Everything Else FormulaProgramming VIA Scanner Input IntroductionQuick Setup Bar Codes BeepUPC-E Interblock Delay Intercharacter DelayBeep Tone see page 40 0 None MediumKeyboard Interface Baud Rate 9600Parity NoneSecond Data Direction for terminal wedge see Send to HostTerminator EnterCode ID Define Code IDScanning Mode Double VerificationTrigger Label TypePpoo Symbologies Group Code 39 seeCheck Digit Not Calculate Interleaved 2 of 5 ITF seeStandard 2 China Postal Code Toshiba Code Code 32 Italian Pharmacy seeTelepen UCC/EAN 128 seeDefine the EAN 128 Fields Separator Define a Separator for Double LabelsDefine Minimum and Maximum Length Code 128 see MSI / Plessey CodeNo Send Check Digit Double Module Code 93 seeCode 11 Special see Codabar seeNo Send Label Code IV and V seeExit EAN-13 see EAN-8Supplement Code see Off / OnDelta Distance Code see Qualifiers Modifiers Special CharactersCode Type Formula FormatSpecial Characters in this section TCP/IP Function Codes for PC Ascii Chart Characters in parentheses represent Extended Code= %H ~ %S Delete %T ? %J NUL %U @ %V \ %L `%W # /C $ /D + /K Programming VIA Scanner Input SP Space Specifications Mechanical Troubleshooting Generic Scanner Troubleshooting TipsProblems and Solutions Problem No output from scanner Troubleshooting BAR Code Test Chart BAR Code Test Char