Unitech MS860 manual EAN-8, Delta Code

Page 57

SCANNER CONFIGURATION MANAGER

Bar Code Symbologies, continued

EAN-8

zEnabled toggles the ability for the scanner to read EAN-8 on or off. Default is “Yes”.

zCode ID is a user-definable identification letter for EAN-8, which is referred to in the “Use Code ID” function on page 45.

Default is letter “FF”.

zSend Leading Digit toggles sending or not sending a leading (‘start bar code’) digit.

Default is “Send”.

zSend Check Digit toggles sending or not sending a check digit. Default is “Send”.

Code 11

zEnabled toggles the ability for the scanner to read Code 11 on or off. Default is “Yes”.

zCode ID is a user-definable identification letter for Code 11, which is referred to in the “Use Code ID” function on page 45.

Default is letter “J”.

zSend Check Digit Number defines the check digit . Default is “Send”.

zSend Check Digit toggles sending or not sending a check digit. Default is “Send”.

zMinimum Length defines the minimum length the user will accept for a valid bar code.

Default is “3”.

zMaximum Length defines the maximum length the user will accept for a valid bar code.

Default is “48”.

Delta Code

zEnabled toggles the ability for the scanner to read Delta Code on or off. Default is “No”.

zCode ID is a user-definable identification letter for Delta Code, which is referred to in the “Use Code ID” function on page 45. Default is letter “D”.

zCalculate Check Digit toggles whether or not to calculate a check digit.

Default is “Yes”.

zSend Check Digit toggles sending or not sending a check digit. Default is “Send”.

55

MS860 WiFi Manual

Image 57
Contents MS860 WiFi Bar Code Scanner Table of Contents Introduction IntroductionQuick Start Important Notes Importantscanner Ndotesaccessories Scanner LED Scanner PartsBuzzer Cradle LEDs Cradle PartsCharging the Scanner How to determine if the scanner needs rechargingNetwork Settings Modifying the WiFi settings IP Address GlossaryWEP Using SCM for Scanner Network Setting Network SettingsNetwork Settings Network Settings Network Settings Using BAR Codes to SET Scanner Network Example IP Space 192.168.1.250 CR Network Settings Example Default CR Installing Virtual COM Network Settings Start Virtual COM Network Settings Vcom should automatically create a virtual com port for Glossary ConfigureWEP the virtual com port using monitor.exe Keep the default settings of the server port and server IP Network Settings Network Settings Start It Up Scanner Configuration Manager Try It Interblock Delay Beeps and DelaysIntercharacter Delay Keyboard WedgeCaps-Lock Function CodeLanguage Use Numeric KeypadParity Baud RateData Bit HandshakingBCC Character RS232Time Out Data DirectionTerminator Scanner PortDouble Verification Use Code IDSettings Function Code RS232 BCC Character Scanner Port EAN-13 Label Code IV or Label Type Scanning ModeAiming Time for Long Range Engine Aim Function for Long Range EnginePreamble PostambleCode Bar Code SymbologiesInterleaved 2 Standard 2 of 5 / Toshiba Code China Postal Code EAN MSI / Plessey Code UPC-A CodabarEAN-13 UPC-EDelta Code EAN-8Label Code IV Supplement Code for UPC-E, ISBN, EAN-13Data Editing QualifierModifier Scanner Configuration Manager Everything Else Formula Arrange FormulasIntroduction Programming VIA Scanner InputBeep Quick Setup Bar CodesUPC-E Intercharacter Delay Interblock DelayBeep Tone see page 40 0 None MediumKeyboard Interface 9600 Baud RateParity NoneData Direction for terminal wedge see Send to Host SecondEnter TerminatorCode ID Define Code IDDouble Verification Scanning ModeTrigger Label TypePpoo Code 39 see Symbologies GroupCheck Digit Not Calculate Interleaved 2 of 5 ITF seeCode 32 Italian Pharmacy see Standard 2 China Postal Code Toshiba CodeTelepen UCC/EAN 128 seeDefine the EAN 128 Fields Separator Define a Separator for Double LabelsDefine Minimum and Maximum Length MSI / Plessey Code Code 128 seeNo Send Check Digit Double Module Code 93 seeCodabar see Code 11 Special seeNo Send Label Code IV and V seeExit EAN-8 EAN-13 seeSupplement Code see Off / OnDelta Distance Code see Qualifiers Special Characters ModifiersCode Type Formula FormatSpecial Characters in this section TCP/IP Function Codes for PC Characters in parentheses represent Extended Code Ascii Chart= %H ~ %S Delete %T ? %J NUL %U @ %V \ %L `%W # /C $ /D + /K Programming VIA Scanner Input SP Space Specifications Mechanical Generic Scanner Troubleshooting Tips TroubleshootingProblems and Solutions Problem No output from scanner Troubleshooting BAR Code Test Chart BAR Code Test Char