Unitech MS860 manual Settings

Page 42

SCANNER CONFIGURATION MANAGER

Settings

Following is a detailed discussion of each of the settings, their at- tributes, and the effects each of these will have on data output from your MS860.

Beeps and Delays

The three attributes for “Beeps and Delays” are: “Beep Tone”, “Interblock Delay”, and “Intercharacter Delay”.

Beep Tone

Select a value from “None” to “High” to set the loudness of the tone, or select “Low to High” or “High to Low” to set the characteristic of the tone.

Default is “Medium”.

Interblock Delay

Interblock delay is the time duration that can be inserted between one block of data and another. This function is analogous to the time duration required between dialing a phone number’s country code and the phone number itself. The interblock delay can be inserted via SCM’s Data Editing function (see page 57).

Default is “10 ms”.

Intercharacter Delay

Intercharacter delay is the time duration between data characters sent from the scanner to the computer. Intercharacter delay is usually inserted when the data flow must be slowed down to accommodate a slower computer.

Default is “1 ms”.

Keyboard Wedge

Your Unitech reader contains a built-in data decoder that translates raw bar code input into Keyboard Scan Code, or ASCII Code in the case of RS232 interface readers, with the result that scanned data exits the reader as if you had typed the text.

The four keyboard wedge parameters are listed on the following page.

MS860 WiFi Manual

40

Image 42
Contents MS860 WiFi Bar Code Scanner Table of Contents Introduction IntroductionQuick Start Important Notes Importantscanner Ndotesaccessories Scanner Parts Scanner LEDBuzzer Cradle Parts Cradle LEDsHow to determine if the scanner needs recharging Charging the ScannerNetwork Settings Modifying the WiFi settings Glossary IP AddressWEP Network Settings Using SCM for Scanner Network SettingNetwork Settings Network Settings Network Settings Using BAR Codes to SET Scanner Network Example IP Space 192.168.1.250 CR Network Settings Example Default CR Installing Virtual COM Network Settings Start Virtual COM Network Settings Vcom should automatically create a virtual com port for Glossary ConfigureWEP the virtual com port using monitor.exe Keep the default settings of the server port and server IP Network Settings Network Settings Start It Up Scanner Configuration Manager Try It Intercharacter Delay Beeps and DelaysInterblock Delay Keyboard WedgeLanguage Function CodeCaps-Lock Use Numeric KeypadData Bit Baud RateParity HandshakingTime Out RS232BCC Character Data DirectionScanner Port TerminatorUse Code ID Double VerificationSettings Function Code RS232 BCC Character Scanner Port EAN-13 Label Code IV or Scanning Mode Label TypePreamble Aim Function for Long Range EngineAiming Time for Long Range Engine PostambleBar Code Symbologies CodeInterleaved 2 Standard 2 of 5 / Toshiba Code China Postal Code EAN MSI / Plessey Code Codabar UPC-AUPC-E EAN-13EAN-8 Delta CodeSupplement Code for UPC-E, ISBN, EAN-13 Label Code IVData Editing QualifierModifier Scanner Configuration Manager Arrange Formulas Everything Else FormulaProgramming VIA Scanner Input IntroductionQuick Setup Bar Codes BeepUPC-E Beep Tone see page 40 0 None Interblock DelayIntercharacter Delay MediumKeyboard Interface Parity Baud Rate9600 NoneSecond Data Direction for terminal wedge see Send to HostCode ID TerminatorEnter Define Code IDTrigger Scanning ModeDouble Verification Label TypePpoo Check Digit Not Calculate Symbologies GroupCode 39 see Interleaved 2 of 5 ITF seeTelepen Standard 2 China Postal Code Toshiba CodeCode 32 Italian Pharmacy see UCC/EAN 128 seeDefine the EAN 128 Fields Separator Define a Separator for Double LabelsDefine Minimum and Maximum Length No Send Check Digit Double Module Code 128 seeMSI / Plessey Code Code 93 seeNo Send Code 11 Special seeCodabar see Label Code IV and V seeExit EAN-13 see EAN-8Supplement Code see Off / OnDelta Distance Code see Qualifiers Modifiers Special CharactersCode Type Formula FormatSpecial Characters in this section TCP/IP Function Codes for PC Ascii Chart Characters in parentheses represent Extended Code= %H ~ %S Delete %T ? %J NUL %U @ %V \ %L `%W # /C $ /D + /K Programming VIA Scanner Input SP Space Specifications Mechanical Troubleshooting Generic Scanner Troubleshooting TipsProblems and Solutions Problem No output from scanner Troubleshooting BAR Code Test Chart BAR Code Test Char