Installation (The installation work must be performed by your dealer without fail.)
$ Transmission signal selection setting
The switches on the COMP and CONNECTOR printed circuit boards must be set to correspond to the signals to be transmitted and components to be connected to the pan/tilt head.
(When shipped, the analog settings are supported.)
OAnalog/IEEE1394 card settings | OWEB card settings | ||
SDI/PR switch: | PR | SDI/PR switch: | PR |
WEB/1394 switch: | 1394 | WEB/1394 switch: | WEB |
WEB/RP 422 switch: RP 422 | WEB/RP 422 switch: WEB | ||
OSDI settings |
|
|
|
SDI/PR switch: | SDI |
|
|
WEB/1394 switch: | 1394 |
|
|
WEB/RP 422 switch: | RP 422 |
|
|
COMP switch
SDI/PR switch
PB switch
Do not change the setting of this switch — use it at the PB position.
COMP printed circuit board
WEB/1394 switch
WEB/RP 422 switch
CONNECTOR printed circuit board
<Note>
OBefore setting the switches, make absolutely sure that the power of the AC adapter which is to be connected to the pan/tilt head is set to OFF.
- 11 -