Panasonic AW-PH360N manual AW-CA50E29

Page 42

Connections

@When the unit is to be connected to a personal computer using the IEEE1394 cable, and the camera and pan/tilt head are to be controlled by the personal computer

Pan/tilt head cable

(AW-CA50E29)

IEEE1394 cable, max. 15 ft. (4.5 m)

DC cable

(UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG, to be locally purchased)

Personal computer

(Windows)

AC adapter:

AW-PS300A

Use the pan/tilt head cable (AW-CA50E29) to connect the unit with the convertible camera containing the plugged-in IEEE1394 card.

Set controller selection switch SW1 to the right side (RP501), and select the transmission signal selection setting that supports the analog/IEEE1394 card.

Use the IEEE1394 cable to connect the unit with the personal computer (Windows).

Install the driver software and control software from the floppy disk supplied with the IEEE1394 card in the personal computer (Windows).

Check that the pan/tilt head and camera can be controlled by the personal computer (Windows) using the control software.

For further details, refer to the IEEE1394 card instructions.

- 42 -

Image 42
Contents AW-PH360N Indicates safety information FCC Note Contents AccessoriesIntroduction Installation precautions Precautions for use Parts and their functions Tilting arm Suspended installation Stand-alone installation $ Assembling the pan/tilt headOAttaching the tilting arm For a soft landing For suspended installationFor stand-alone installation For a precise landingOsdi settings $ Transmission signal selection settingOAnalog/IEEE1394 card settings Oweb card settings Connector printed circuit board$ Setting the cable compensation circuit of video signals When using the AW-RP605A controllerWhen using the AW-RP400 controller $ Installing the pan/tilt head Suspended installation $ Mounting the cameraMounting example when the camera side is heavy Mounting example when the lens side is heavyOAttaching the chain With the AW-E350/AW-E650With the AW-E655/AW-E750/AW-E860 OAdjusting slack in the chain OMounting a cameraWith the AW-E350/AW-E650 With the AW-E655/AW-E750/AW-E860 Connections Monitor Connections Compensation unit $ Connecting the connector panel RS-232C control Zoom lens RS-232C cable AW-CA28T9$ Head connector panel As viewed from cable endConnector Pb OUT connector $ Connecting the AC adapter for use with the pan/tilt head DC 12V in terminal board$ Connection examples 10BASE-TAW-PS300A AC adapter AW-PS300A Equivalent to UTP Category 5 straight Cable, max ft 10 m Equivalent to Belden AW-RP605A Coaxial cable Camera cable supplied Panel is used to control the camera Coaxial cable Belden 8281, max ft m Color monitor AW-RC400 Connections Personal computer Belden 8281, max AW-CA50F29 AW-CA50E29 Limiters $ Setting/releasing the limiters OFor the controller AW-RP301/AW-RP305/AW-RP501/AW-RP505OFor the controller AW-RP605A OFor the controller AW-RP400 $ Replacing the motor Replacement of consumable parts$ Replacing the battery $ Replacing the gearSpecifications $ Functions/performance Page Page Panasonic Broadcast & Television Systems Company