Configure the settings relating to the flange-back [BACK-

FOCUS]

Select the method of the flange-back length adjustment and adjust the flange-back length minutely. The settings can be configured on the "BACK-FOCUS SETUP" page. Before adjusting the flange-back length, adjust the lens first. (Operating instructions (book))

Refer to the operating instructions (book) for descriptions of how to display the "BACK-FOCUS SETUP" page.

<About the flange-back length adjustment>

The flange-back length is the distance between flange surface and the focal point.

Important:

The "ABF" (auto back focus) function is for adjustment of the flange-back length at the installation, and for focus compensation when shifting between colour and B/W after the installation. This function is not supposed to be

used for sequential action such as the auto focus function.

It is necessary to adjust the flange-back length again when images become out-of-focus caused by aging of the lens and the environment change, etc.

Note:

The flange-back length adjustment can be performed using the operation buttons on the camera (Operating instructions (book)).

<BACK-FOCUS SETUP page>

**BACK-FOCUS SETUP**

Notes:

ABF

PUSH SW

 

MANUAL-ADJ

C/L B/W AUTO SETUP-SW LOCK OFF

NEARFAR

..................

INDICATOR XXXX

RET TOP END

"ABF" is available only when "OFF", "X2 AUTO" or "X2 FIX" is selected for "SENS UP".

"AUTO" of "C/L ←→ B/W" is available only when "OFF", "X2 AUTO" or "X2 FIX" is selected for "SENS UP".

[ABF]

When the [SET] button is pressed after moving the cur- sor onto "PUSH SW", the auto-back focus function will be activated and adjust automatically the flange-back length to a subject located at the centre of the screen.

[MANUAL-ADJ]

To adjust the flange-back length finely, press the [SET] button after moving the cursor onto "MANUAL-ADJ". The flange-back length can be adjusted manually using the [Left] and [Right] buttons.

Notes:

The flange-back length position will set to the default position for the CS-mount by pressing both the [Left] and [Right] buttons for 2 seconds or more.

A value displayed for "INDICATOR" is an indication for the flange-back length adjustment. When the value becomes larger, the displayed image will be sharper.

[C/L ←→ B/W]

Select a method of the flange-back length adjustment from the following.

AUTO: Adjusts the flange-back length automatically to correct out-of-focus which may be caused when switching between the colour image display and the BW image display.

PRESET: When switching between the colour mode and the B/W mode, the flange-back length position will move to the preset position of each mode. The latest adjusted flange-back length positions for each mode will be memorized automatically as the preset posi- tion.

FIX: The position will be fixed after adjusting the flange- back length manually or using the auto back focus function (ABF).

Default: AUTO

52

Image 52
Contents WV-NP1004 Contents About these operating instructions PrefaceTrademarks and registered trademarks Monitor images from a single camera Monitoring Images on a PCStep About the Live One shot button 3Main areaAvailable operations when live images are displayed Operation DescriptionImages will be automatically switched between colour and B/W Monitor images from multiple cameras Notify of alarm occurrences by e-mail Action at an Alarm OccurrenceTransmit an image onto a server automatically Transmit Images onto an FTP Server Obtain images on the SD memory card Save images on the SD memory cardAbout SD memory card Use FTP About the Network Security of the Camera Access restrictions by changing the Http portEquipped security functions How to display the setup menu How to operate the setup menu About the operation window Network setup button Maintenance buttonHelp button 1Status display areaConfigure the basic settings of the camera Basic setup Configure the basic settings BasicDefault OFF Link/Access LED Daylight saving SummertimeConfigure the settings relating to the NTP server NTP About SD memory card Information about SD memory cardIndication Description FormatConfigure the settings relating to Jpeg image JPEG/MPEG-4 Image capture size/Scan modeDefault 5 fps Image qualityConfigure the settings relating to MPEG-4 image JPEG/MPEG-4 About the operation panel Configure the settings relating to audio Audio Configures the multi-screen settings Multi-screen setup IP AddressNumber of characters for the IP address 1 Number of characters for the camera title 0Configure the alarm settings Alarm setup Configure the settings relating to the alarm action AlarmAlarm image FTP transmission Default blank Transmission intervalDirectory Number of characters for the directory nameDefault OFF External terminal output setup Default Latch Alarm outputDefault Open Pulse widthDefault None Default Middle StepSet the VMD areas VMD area Delete the set VMD area Default OFF Address Mail notificationNumber of characters for the mail subject 0 Mail bodyPanasonic alarm protocol Default OFF Destination portAvailable port number 1 Default Retry times Available retry times 1 Default IP addressUser authentication Default OFF User nameDefault blank Password Retype password Number of characters for the password 4 32 charHost authentication Configure the settings of the servers Server setup Configure the settings relating to the mail server MailConfigure the settings relating to the FTP server FTP FTP modeDefault Passive FTP server address Number of characters for the FTP server addressConfigure the network settings Network Configuring the network settings Network setupDhcp DNS Configure the settings relating to Ddns Ddns Default OFF Host nameDdns Number of characters for the host name 1 64 charConfigure the settings relating to Snmp Snmp Access intervalCamera location Number of characters for the camera location 0Default OFF Directory Default blank File nameDefault blank Interval FTP periodic transmissionHow to configure the schedule settings How to delete the set schedule Maintenance of the camera Maintenance Error messageCheck the system log System log Time & dateUpgrade the firmware Upgrade How to upgrade the firmwareInitialize setup data Initialize setup data and Html dataInitialize/restart the camera Initialization Initialize Html dataConfigure the settings relating to the camera operations Camera IDALC/ELC ShutterAGC Sens UPSync White BALBW Mode DNRPrivacy Zone EL-ZOOMABF Configure the settings relating to the flange-back BackMANUAL-ADJ SETUP-SW Lock ABF AutoConfigure the settings on the Special Setup Configure the network settings Network IP AddrNetmask GatewayCamera title can be edited and displayed on the screen Configure the detailed settingsAbout character entry To cancel the mask setting Default OFF StepCompensate backlight Adjust white balance finely Configure the B/W mode settings Default High StepDefault 30 sec Step Default onSet the privacy zone Adjust the electronic zoom Correct image defects blemishes such as scratches Error indications relating to Smtp Error indications relating to FTPAbout the Displayed System Log Category Cause DescriptionError indications relating to NTP Error indications relating to DdnsOther error Troubleshooting Symptom Cause/solutionSymptom Symptom Cause/solution Reference Pages Solutions Reference Pages Osaka, Japan N1205-0 3TR004271AAA